Page 13 - QR DIAMOND DBR-32HD
P. 13

PULL  
                                  Set the hook in the correct starting position, make sure that the
                                  mode control lever is in the PULL position and fit the rebar as shown.
                                  Pull the trigger switch until the desired angle is attained.
                                  N.B. It is important that the rebar be properly fitted in the hook and
                                  against the rollers. 

                                    Option: Large radius bending hook
                                    Large radius bending hook available (R.50mm)

                                           The tool can rotate on the housing unit according to
                                           the working position. Please change the direction of
                                           the bending hook (see photo) to suit. 

7. Switch “OFF”. Disconnect tool from outlet when not in use and before cleaning,
adjusting or servicing. Do not disconnect plug from outlet by pulling the cord.
Always check that the switch is OFF before plugging in.

  POINTS OF ATTENTION
  1. Do not cover air vents.
  WARNING: If vents are covered, motor will overheat and may burn out.
  2. If hydraulic oil exceeds 70°C (158°F) in temperature, power will drop.
  Allow unit to cool before resuming operation. (Be particularly careful in summer,
  when the aluminium pump case heats up quicker.)
  3. If a drop in power is observed and motor is an unusually hot, check motor carbon
  brushes.

                                                                         11 
   8   9   10   11   12   13   14   15   16   17