Page 76 - Catalogue - cuvettes and solid-state calibration standards
P. 76

Absorptiometer /colorimeter cuvettes

Type 96         All dimensions in mm, volumes in mL

Length          External                             Internal
  28.0                                                Width
  28.0          Width     Height    Length                     Volume
                                                        5.0      4.400
                9.0       40.0      24.0               10.0      8.800

                14.0      40.0      24.0

Part Number     Description                                                                 Price
LC-96-G-5       Absorptiometer/Colorimeter cuvette, optical glass, lightpath 5 mm           24.95
LC-96-G-10      Absorptiometer/Colorimeter cuvette, optical glass, lightpath 10 mm          24.95
LC-96-Q-5       Absorptiometer/Colorimeter cuvette, UV quartz, lightpath 5 mm               77.05
LC-96-Q-10      Absorptiometer/Colorimeter cuvette, UV quartz, lightpath 10 mm              77.05
LC-96-I-5       Absorptiometer/Colorimeter cuvette, IR quartz, lightpath 5 mm               83.37
LC-96-I-10      Absorptiometer/Colorimeter cuvette, IR quartz, lightpath 10 mm              83.37

Flow cytometry cuvettes

Type 526        All dimensions in mm, volumes in mL

Lightpath                 External                             Internal
    0.25                                                        Width
                Length    Width     Height           Length      0.25    Height     Volume
                                                       0.25               20.0       0.010
                4.25 4.25 20.0

Part Number     Description                                                                  Price
FF-526-UV-0.25  Flow cytometry cuvette, UV quartz, lightpath 0.25 mm                        486.32

 Type 77        All dimensions in mm, volumes in mL

Lightpath                 External                             Internal
    2.0                                                         Width
                Length    Width     Height           Length                         Volume
                                                        2.0       2.0                0.110
                10.5 10.5 27.4

Part Number     Description                                                                  Price
FF-77-UV-2      Flow cytometry cuvette, UV quartz, lightpath 2 mm                           310.74
FF-77-IR-2      Flow cytometry cuvette, IR quartz, lightpath 2 mm                           314.53

68