Page 2 - BrownhillHomes_Lux
P. 2

LUX  INCLUSIONS


























        PRELIMINARIES                  -  Working drawings (Brownhill Homes Design Only).
                                       -  Building permit (excluding planning permits and/or dispensations if required).
                                        Energy Rating Report (Brownhill Homes design only).
                                       -
                                        90-day maintenance period.
                                       -
        SITE WORKS AND                 -  Engineered designed ‘M Class’ concrete slab (site specific). Excludes excava-
        CONNECTIONS                     tion of rock and excess spoil removal.
                                        Site costs and connections based on land size up to 600m2.
                                       -
                                        Balance cut and fill, maximum 6m setback to house, and 300mm fall over
                                       -
                                        building area.
                                        Stormwater and sewer connection within allotment (up to 600m2 land size)
                                       -
                                        and to a maximum sewer depth of 1.5m.
                                        Underground power, gas (if available), and water lead-in from existing meter.
                                       -
                                        Physical barrier Part A PVC slab penetrations. Part B termite treatment to pe-
                                       -
                                        rimeter of concrete slab.
                                        Temporary Fencing for the full duration of build (up to 20m in length).
                                       -
                                        Crushed rock to driveway as required.
                                       -
        INTERNAL                       -  Square set cornice to Main Living areas of single storey home or entire
        FEATURES                        ground floor of a double storey home, with 75mm cove cornice to remainder.
                                       -  10mm plasterboard to walls and ceiling.
                                        2700mm nominal ceilings to single storey homes and ground floor of double
                                       -
                                        storey homes. 2550mm nominal ceilings to first floor (design specific).
                                        67mm x 18mm nominal MDF skirtings and architraves.
                                       -
                                        Staircase: Staircase Closed American Oak ’Veneer” stained hardwood treads
                                       -
                                        and risers, painted stringer, bullnose/square edge risers and stained rectan-
                                        gular/round hardwood handrail.
                                        Choice of either black/grey vertical square rod balustrading.
                                       -

        FRAMING                        -  90mm MGP10 timber framing, including engineer designed timber posi strut
                                        floor.