Page 2 - QU220981 ACFS (VIC)
P. 2
1 2 3 4
3900
2600
A 11200 11200 A
TB90 B150
2600 C/E
A 4 A 4 3900 C/E
3900
2600
9600 9600 9600 9600
TB90 TB90 B150 B150
2600 C/E 2600 C/E
A 4 A 4 A 4 A 4
3900 C/E 3900 C/E
2600
8000 8000 8000 7950 7950
TB90 TB90 TB90
2600 C/E 2600 C/E 2600 C/E B150 B150
A 4 A 4 A 4 A 4 A 4 A 4
3900 C/E 3900 C/E
B B
6400 6400 6400
TB90 TB90 TB90 6300 6300
2600 C/E 2600 C/E 2600 C/E
A 4 A 4 A 4 A 4 A 4 A 4 B150 B150
SPLICE LINE SPLICE LINE SPLICE LINE SPLICE LINE 3900 C/E SPLICE LINE 3900 C/E
11250 11250
4800 4800 4800
TB90 9650 TB90 TB90 9650
2600 C/E 2600 C/E 2600 C/E
A 4 A 4 A 4 A 4 A 4 A 4
8050
3200 3200 3200
TB90 TB90 TB90
2600 C/E 2600 C/E 2600 C/E
A 4 A 4 A 4 A 4 A 4 A 4
C C
1600 1600 1600
TB90 B125 B125
2600 C/E
A 4 A 4
2600 C/E 2600 C/E
BAY TYPE A BAY TYPE B BAY TYPE C BAY TYPE DT1 BAY TYPE DT2
D 1340mm SPRINKLER D
C CLEARANCE ZONE
FROM UNDERSIDE
OF ROOF SHEET
600 650 750 850 1000 800 700 600
E E
TB90 TB90 TB90 TB90 B150 TB90 TB90 TB90
2600 C/E 2600 C/E 2600 C/E 2600 C/E 2600 C/E 2600 C/E 2600 C/E
A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4
3900 C/E
TB98 TB98 TB98 TB98 TB90 TB90 TB90 TB90 B150 TB90 TB90 TB90 TB98 TB98 TB98 TB98 TB98 TB98
2600 C/E A 4 A 4 2600 C/E A 4 A 4 2600 C/E A 4 A 4 2600 C/E A 4 A 4 2600 C/E A 4 A 4 2600 C/E A 4 A 4 2600 C/E A 4 A 4 2600 C/E A 4 A 4 2600 C/E A 4 A 4 2600 C/E A 4 A 4 2600 C/E A 4 A 4 2600 C/E A 4 A 4 2600 C/E A 4 A 4 2600 C/E A 4 A 4 2600 C/E A 4 A 4 2600 C/E A 4 A 4 2600 C/E A 4 A 4
3900 C/E
DRAWING FOR QUOTATION ONLY FINAL LAYOUT SUBJECT TO FULL SITE SURVEY
Customer: AUSTRALIA DRIVE
DRAWING APPROVAL: THE PROPOSED LAYOUT IS CONCEPTUAL ONLY. IT IS THE CLIENT VIC
RESPONSIBILITY TO ENSURE ALL STATUTORY & BUILDING CODE CONCEPTUAL ELEVATION
F REQUIREMENTS ARE MET. THE PROPOSED LAYOUT HAS BEEN F
C O P Y R I G H T PROVIDED AS A GUIDE FOR THE CLIENT PLANNING PURPOSES. IT IS Drawing No.: Rev No.: G
C APPROVAL BY (PRINT NAME & SIGNITURE):
R E S E R V E D ASSUMED THE EXISTING SURFACE ONTO WHICH THE INSTALLATION IS QU220981
TO BE BUILT IS CAPABLE OF SUPPORTING THE STRUCTURE INCLUDING Sheet No.: 3
T H E D R A W I N G I S P R O T E C T E D B Y POSITION:__________________ DATE: _____________ ITS CONTENTS AND STRUCTURALLY ADEQUATE TO TAKE INDUCED
COPYRIGHT AND IS THE PROPERTY OF
PREMIER RACKING. NO PUBLICATION, LOADS AND FLOOR FIXING. WE RECOMMEND YOU OBTAIN Size: Drawn By: FSA Date: 18.08.22
COPYING OR PARTIAL COPYING IS COMMENT: _______________________________________ INDEPENDENT VERIFICATION THAT THE EXISTING STRUCTURE IS G BAY C ADDED FSA 18.08.22 BP 1300 724 584
PERMITTED UNLESS AGREED TO IN _________________________________________________ A3 Checked: BP Scale: DNS
WRITING WITH PREMIER RACKING. CAPABLE OF SUSTAINING THE LOADS/FORCES. Rev. Description By Date Chkd
1 2 3 4