Page 15 - Delco Sales - 2022 Irrigation Playbook Draft 1
P. 15
4 3 2 1
NOTE 1:
5Xs MEANS 5 TIMES PIPE’S INNER DIAMETER AND
1 PLASTIC VALVE BOX TO 10Xs MEANS 10 TIMES PIPE’S INNER DIAMETER
PROVIDE ACCESS.
NOTE 2:
2 3M DBR/Y-6 SPLICE KIT OR EQUIVALENT FOR 1-INCH PIPE INSTALLATIONS, THIS ANGLE IS ESPECIALLY
DIRECT BURIAL SPLICE KIT IMPORTANT AND SHOULD BE SET AT 45 DEGREES FOR
3 DIRECT BURIAL 1 PAIR, TWISTED MOST ACCURATE METER OPERATION
B 1 SHIELDED CABLE. RECOMMENDED NOTE 3: B
MINIMUM CONDUCTER SIZE 18 AWG. BURRIED CABLE ENROUTE TO IRRIGATION CONTROLLER
3 RATED FOR DISTANCES UP TO 2,000 FT (610 M)
4 QS200 ULTRASONIC FLOWMETER
INSTALL AT
5 TEE COMPATIBLE WITH QS200 (FLOMEC QS200 TEE ANGLE, IF
RECOMMENDED FOR BEST RESULTS). SELECT TEE POSSIBLE
2 SIZE PER APPLICATION FLOW RATES REQ’D (SEE DATA SHEET) SEE NOTE 2
6 QUICK RELEASE PIN
6
4 SEE 7 GRAVEL - GRAVEL SHALL BE PLACED AT BOTTOM OF METER
A NOTE 3 TEE AND SHALL BE A MINIMUM OF 10-INCH THICK (10-INCH DEEP)
5
X X
DOWNSTREAM UPSTREAM
X X
A
X X X X X X SECTION A-A
01
5Xs 7 10Xs
A N.T.S. A
SEE NOTE 1 QS200 FLOWMETER INSTALLATION
00 FLOMEC FLOWMETER INSTALLATION FLOMEC.net
FLOMEC.net
N.T.S. IND-1125 REV B Great Plains Industries, Inc. Australia +61 2 9540 4433 FLOMEC.net
Great Plains Industries, Inc. Australia +61 2 9540 4433 FLOMEC.net
4 3 2 1