Page 23 - Delco Sales - 2022 Irrigation Playbook Draft 1
P. 23
4 3 2 1
1 PLASTIC VALVE BOX TO NOTE 1:
PROVIDE ACCESS. 5Xs MEANS 5 TIMES PIPE’S INNER DIAMETER AND
10Xs MEANS 10 TIMES PIPE’S INNER DIAMETER
2 3M DBR/Y-6 SPLICE KIT OR EQUIVALENT
DIRECT BURIAL SPLICE KIT NOTE 2:
BURIED CABLE ENROUTE TO IRRIGATION CONTROLLER
3 DIRECT BURIAL 1 PAIR, TWISTED
1 SHIELDED CABLE. RECOMMENDED NOTE 3:
B MINIMUM CONDUCTER SIZE 18 AWG. PVC UNIONS OR COUPLERS ARE REQUIRED B
3 RATED FOR DISTANCES UP TO 2,000 FT (610 M). FOR QS100 INSTALLATION
ENSURE A SERVICE LOOP (EXTRA WIRE LENGTH) IS PROVIDED
AT THE FLOW SENSOR IN CASE MAINTENANCE IS NEEDED
4 QS100 ULTRASONIC FLOW SENSOR
5 FLOW DIRECTION ARROW
2
6 GRAVEL - GRAVEL SHALL BE PLACED AT BOTTOM OF QS100 INSTALL UPRIGHT,
AND SHALL BE A MINIMUM OF 10-INCH THICK (10-INCH DEEP) AS SHOWN
4 SEE
NOTE 2
A 01 5 5
NOTE 3 NOTE 3
X X
UPSTREAM X X DOWNSTREAM
A
X X X X X X
10Xs 6 5Xs 01 TOP VIEW 02 SECTION A-A
N.T.S. N.T.S.
A A
SEE NOTE 1
QS100 FLOW SENSOR INSTALLATION
00 FLOMEC FLOW SENSOR INSTALLATION
N.T.S. IND-1125 REV-
FLOMEC.net
FLOMEC.net
Great Plains Industries, Inc. Australia +61 2 9540 4433 FLOMEC.net
Great Plains Industries, Inc. Australia +61 2 9540 4433 FLOMEC.net
4 3 2 1