Page 374 - Workshop Manual - Aumark (BJ1051)
P. 374

04-230
                                                Diagnosis- illumination
          Diagnostic procedure

          1.     Checking harnesses
          (a)     Use a multimeter to measure resistance of harness between pin 5 of small light relay R32
                 and pin 3 of B105.
          (b)     Use a multimeter to measure resistances of grounds C237 and C238.
                 Resistance: ≤2Ω
          (c)     Use a multimeter to measure resistance of harness between pin 3 of B105 and ground.
              Resistance: >1MΩ
          Are check results normal?
   04     Yes > Replace bulbs.
          No > Repair or replace harnesses.








































































                                                                                                         Page 374