Page 480 - Workshop Manual - Aumark (BJ1051)
P. 480

04-336
                                                    Diagnosis- combination meter

                                                                (b)     Check if fuse F15 (10 A) and F17 (7.5
                                                                        A) in body fuse block have been blown.
















   04




               Is check result normal?
               Yes >   Go to step 2.
               No >    Go to step 4.
               2.     Checking power circuit of combination meter

                                                                (a)     Disconnect connector of combination
                                                                        meter B033.












                                                                (b)     Use a multimeter to measure voltages to
                                                                        ground of connector pins 2 and 10 of
                                                                        combination meter B033 respectively.
                                                                        Voltage: battery voltage










               Are check results normal?
               Yes >   Go to step 3.
               No >    If battery voltage is not available on connector pin 2 of combination meter B033, repair line
                      open from fuse F15 (10A) to connector pin 2 of the meter.
                      If battery voltage is not available on connector pin 10 of combination meter B033, repair
                      line open from fuse F17 (7.5A) to connector pin 10 of the meter.