Page 30 - Gi_September2021
P. 30

igem news – yppc

                 THE IMPACT OF POWER GENERATION



                 AND BIOMETHANE ON ANALYSIS




















































                 By David Noakes, Network Support Engineer at Wales & West Utilities  when the electricity demand is high.
                                                                                   On a typical day, that means switching
                 WALES & WEST UTILITIES’ (WWU)    and biomethane analysis completed is   on during the two peaks on a typical
                 ambition is “to deliver outstanding   of a high standard and best replicates   diurnal swing.
                 levels of gas safety, reliability and   the site operating on our network.   As the PG site switches on rapidly,
                 customer service, so that we are trusted   Considering the rapid development of   we witness a sudden drop in pressure.
                 and valued by millions of people we   these sites over the last few years, it   Likewise, when the site switches off,
                 serve every day”. This is delivered by   was paramount that we stayed ahead   we see a sudden increase in pressure.
                 ensuring our work abides by WWU’s   of the analysis curve and this paper   It is this occurrence that needs to be
                 priorities:                      will demonstrate the impact of these   analysed carefully.
                 1.  Demanding safety always      sites and the changes required to cope
                 2.  Driving outstanding service  with the demand.                 Power generation analysis
                 3.  Delivering value for money                                    A change was needed in our analysis
                 4.  Doing all we can to provide a   Power generation              process to analyse ramp rates. This
                   reliable gas supply and promote   The rise and impact of power   saw the introduction of fast transient
                   sustainability                 generation                       (FT) analysis.
                 5. Designing our future          From 2014 onwards, the amount of   FT analysis using Synergi allows us
                   All five priorities must be taken into   PG requests we received grew rapidly,   to examine the ramp rates of PG sites
                 account when conducting network   reaching a peak in 2019 of almost 600   more closely. Using a 36-minute profile,
                 analysis, especially when considering   requests. In the last four years, we have   we can simulate the site switching
                 new and expanding load types such as   gone from having 11 connected PG sites   on using, for example, a two-minute
                 power generation (PG) and biomethane.  to 41 with a further 28 accepted sites   ramp rate and the site switching
                   In my current role, I am responsible   looking to connect.      off instantaneously, simulating an
                 for ensuring that the power generation   Peaking generators generally operate   emergency switch off.