Page 117 - Arch binder
P. 117

Operable Partitions          MODEL 2010 STACK ARRANGEMENTS
                                      10 22 26 (10650)











                                                                  Standard Perpendicular Stack
                                                                  Perpendicular stacking allows individual panels to be located at
                                                                  one (1) or both ends and stored perpendicular to the wall’s
                                                                  installed position.





                Pocket Width
              *
             *
          Stack               [457]
          *  Depth            1'-6"                               Optional Parallel Stack
                              Min.
                                                                  In contrast to perpendicular stacking, Individual Panel
                                                                  arrangements may also be stored parallel to the wall’s installed
                                 [914]                            position, at one (1) or both ends.
                                3'-0" Min.
                            Note:
                            Single Pocket Door
                            swinging inward.


                                                                  Optional Remote Stack
                                                                  For more complex wall system layouts, or when space or other
                                                                  room constraints dictate, Individual Panels may be located
                                                                  remotely from the wall’s installed position, at one (1) or
                                                                  both ends.
          Pocket Width

         *
         *
                 *
               Stack Depth



        Stack Depth*                                               Pocket Width**
                                                                   The width of the pocket is determined by the widest panel in
        The overall depth of the stack area, as required for panel storage,   the wall run. For specifi cation purposes, assume the widest
        is dictated by the total number of panels in the wall system.   panel is 4'-0" (122 cm) maximum. Pocket width may be
        KWIK-WALL’s Model 2010 - Individual Panels / Curve & Diverter   calculated as follows:
        panels require an average stack depth of 3 1/ 4" [83] per panel. To
        determine the stack depth, calculate as follows.
                                                                   If Adjustable or Operable Bottom Seals are specifi ed:
                            1
        Number of Panels x 3 / 4" [83]                             Panel Width + 7" [178]
                                                                          1
                                                                   (allows 3 / 2" [89] for hand clearance on each side)
           *Note:  Additional stack depth is required for wall systems
                                                                   If Automatic Bottom Seals are specifi ed:
             containing the following type of panels:
                                          3
                     • Expander Panel Closure or Pass Door Panel:  / 4" [19]  Widest Panel + 10" [254]
                     • Hinged Panel(s) Closure: 4" [102]           (for actuator clearance on one side)
                     • Pocket Door(s): 6" [152]
                                                                   plus
           **Note:  For wall systems that include Pocket Doors, please
                                                                    1
               reference KWIK-WALL’s “ 2000 Series Pocket Doors” brochure   3 / 2" [89]
               for pocket layout dimensions and applications.      (for hand clearance on the other side)
                                                                                                                 8
                                                                                                               04-18
                  Dimensions in [ ] are millimeters. Contact your local distributor for additional assistance or visit www.kwik-wall.com
   112   113   114   115   116   117   118   119   120   121   122