Operable Partitions
                                      10 22 26 (10650)        PART 1 - MODEL 2030 GENERAL SPECIFICATION


    1.01 WORK INCLUDED                                        E. ASTM A 653:  Specifi cation for General Requirements for Steel
    A. Operable Wall System shall be furnished, installed and serviced by        Sheet, Alloy-Coated (Galvanneal) by the Hot Dip Process.
         KWIK-WALL's authorized distributor, in compliance with the   F. ASTM C 423:  Standard Test Method for Sound Absorption and
         architectural drawings and specifi cations contained herein.       Sound Absorption Coeffi cients by the Reverberation Room
                                                                   Method.
    1.02 RELATED WORK                                         G. CCC-W-408A:  Federal Specifi cation which applies to Vinyl
                                                                   Coated Wall Coverings.
    A. Structural Support: Structural support system required for   H. CFFA-W-101-D:  Chemical Fabrics and Film Association
         suspending the operable wall shall be designed, installed and         Quality Standard for Vinyl Coated Fabric Wall Coverings
         pre-punched by others, in accordance with ASTM E 557 and
         KWIK-WALL's shop drawings.
                                                              1.06 SUBMITTALS
    B. Insulation: Sound insulation and baffl es for the plenum area above
         the track system, under the permanent fl oor, inside air ducts   A. KWIK-WALL shall provide written technical information and
         passing over or around the operable wall, and in permanent walls        related detail drawings, which demonstrate that the products
         adjoining the operable wall system shall be by others, in        comply with contract documents for each type of operable
         accordance with ASTM E 557.                               partition specifi ed.
                                                              B. KWIK-WALL shall provide detailed engineering drawings
    C. Opening Preparation: Proper and complete preparation of the        featuring track plan, panel elevation, horizontal and vertical
         operable wall system opening shall be by others in accordance with        details and beam punching template as required.
         ASTM E 557, and shall include fl oor leveling; plumbness of   C. KWIK-WALL shall provide written test report of the independent
         adjoining permanent walls; substrate and or ceiling tile enclosures        acoustical testing laboratory certifying the attainment of the
         for the track system; and the painting and fi nishing of trim and        specifi ed STC rating, upon request.
         other materials adjoining the head and jamb areas of the operable   D. KWIK-WALL shall provide written instructions specifying the
         wall. Any permanent wall(s) receiving an adjustable or fi xed wall        proper operation and maintenance of the operable wall system.
         jamb will require internal structural blocking in order to secure the   E. KWIK-WALL shall provide a color selector demonstrating the
         jamb to the permanent wall. Refer to a copy of the shop drawings        manufacturer's selections of the specifi ed fi nish material. Samples
         for additional details.                                   shall consist of actual swatches of the specifi ed fi nish material.

    1.03 SYSTEM DESCRIPTION
                                                              1.07 DELIVERY, STORAGE AND HANDLING
    A. The operable wall system shall consist of Hinged Pair Panels that
         are top supported by one (1) carrier.  Featuring panels hinged             A. Panels shall be individually wrapped in a protective plastic
         together in evenly matched pairs (groups of two (2)), unless        covering to keep panels clean during delivery, storage and
         otherwise specifi ed.                                      handling.
                                                              B. Panels shall be stored on edge and above the fl oor on cushioned
    B. The operable wall system shall consist of acoustically rated panels        blocking in a dry and ventilated area, protected from humidity and
         tested in accordance with ASTM E 90 and ASTM E 413 test        temperature extremes.
         procedures, and shall have achieved a STC rating as specifi ed
         herein (see "Acoustical Performance" article listed under   1.08 SEQUENCING / SCHEDULING
         Part 2 - Products).
                                                              A. Beam Punching: KWIK-WALL shall provide beam punching
    1.04 QUALITY ASSURANCE                                         template drawing detailing the anchor locations for the suspended
                                                                   track system (as required for Drop Rod Mounting), as required for
    A. The operable wall shall have been tested in an independent        the fabrication and installation of structural overhead support
         acoustical testing laboratory in accordance with ASTM E 90 and
         ASTM E 413 test procedures.                               by others.
                                                              B. Track Installation: Scheduling of operable wall track installation
    B. The operable wall panel construction and fi nish materials shall        shall occur after structural overhead support has been properly
         consist of Class A rated materials (except as noted, under        and completely fabricated and installed by others.
         “Finishes” Part 2 – Products) in accordance with ASTM E 84.  C. Panel Installation: Operable wall panel installation shall occur
    C. The operable wall shall be installed by KWIK-WALL's         after fi xed wall substrate construction is properly and completely
         authorized distributor in accordance with ASTM E 557.       installed by others, as required to protect panels from ongoing
                                                                   adjacent construction.
    1.05 REFERENCES
    A. ASTM E 90:  Laboratory Measurement of Airborne-Sound   1.09 WARRANTY
         Transmission Loss of Building Partitions.            A. KWIK-WALL shall warrant each partition and its component
    B. ASTM E 413:  Determination of Sound Transmission Class (STC).  parts to be free from defects in material and workmanship for a
    C. ASTM E 557:  Architectural Application and Installation of   period of fi ve (5) years from the date of delivery to the original
         Operable Partitions.                                 purchaser, when installed by an authorized KWIK-WALL distributor
    D. ASTM E 84:  Surface Burning Characteristics of Building   (see actual warranty on Page 12 for details and limitations).
         Materials.






                                                                                                                 2
                  Dimensions in [ ] are millimeters. Contact your local distributor for additional assistance or visit www.kwik-wall.com  12-16