Operable Partitions MODEL 3010GL PART 2 - PRODUCT SPECIFICATIONS
10 22 26 (10650)
1. Standard Vinyl: consisting of Type II, reinforced
2.01 ACCEPTABLE MANUFACTURER vinyl weighing 20 oz./lin. yd. (620 g/lin. m). Upgrade Vinyl
A. Operable walls shall be Series 3000, Model 3010GL Individual shall meetor exceed CCC-W-408A-D and CFFA-W-101-B
Panels / Curve & Diverter as manufactured by KWIK-WALL quality standards.
Company.
2. Optional Upgrade Fabric: consisting of fade and tear
2.02 PANEL CONSTRUCTION resistant fabric that resists water-based stains weighing 13
oz./lin. yd.(403 g/lin. m).
A. Panel Dimensions: Standard panel dimension shall be a nominal
4" [101.6] thick. 3. Optional Basics Carpet: consisting of acoustically absorbent,
B. Panel Frame: Steel frame shall be 16-gauge galvanneal steel, non-woven needle punch fi bers fused to prevent fraying and
which meets or exceeds ASTM A 653 requirements. Frame shall unraveling of material weighing 28.5 oz./lin. yd.
be all-welded construction with steel corner supports and (884 g/lin.m). Basics Carpet shall achieve a minimum NRC
crossbracing reinforcement. Panel frame shall be Class A rated, rating of .20 (applied over gypsum substrate) accordance
fi re retardant, non-combustible and non-corrosive in accordance with ASTM C 423.
with ASTM E 84. Panel frame shall be designed to accept two
(2) pieces of 1/4" [6.35], thick glass in opening cut out. (Glass 4. Optional Upgrade Carpet: consisting of acoustically
opening size will vary based on panel height and width. Refer to absorbent, non-woven needle punch fi bers fused to prevent
shop drawings for sizes.) fraying and unraveling of material weighing 23 oz. / lin. yd.
(713 g / lin. m). Upgrade Carpet shall achieve a minimum
C. Panel Skins: Panel skins shall be Class A rated in accordance with NRC rating of .25 (applied over gypsum substrate) in
ASTM E 84. Panel skin material shall consist of (select): accordance with ASTM C 423.
1. Standard Acoustical Substrate: consisting of structural
acoustical substrate pressure laminated to booth side of the 5.Optional Wood Veneer: consisting of unfi nished fl at cut wood
steel frame to form a rigid, unitized and structural panel. veneer laminated to 1/2" [12.7] thick particle board core.
Veneer shall be book / running matched within a panel, and
2. Optional Steel Skins: consisting of minimum 22-gauge
tension-leveled galvanneal steel, pressure laminated to a vertically edge banded if Trimless astragals are specifi ed.
structural acoustical backer and mechanically fastened Notes: Optional Class "A" rated particle board is available.
Acoustical substrate STC ratings apply for Wood Veneer panel
to the steel frame to form a rigid, unitized and structural construction.
panel.
D. Panel Hinges: Panel hinges shall be architectural grade, full leaf 6. Optional High Pressure Laminate: consisting of general
butt hinges. purpose plastic laminate pressure bonded to ½" [12.7]
particle board core, and edge banded if Trimless astragals
E. Panel Weight: Maximum panel weight shall be 11.3 - 12.3 lbs./ are specifi ed.
2
2
ft. (55 - 60.5 kg/m ) depending on STC rating, size and options (Note: Acoustical substrate STC ratings apply for High Pressure
selected. Laminate panel construction.)
2.03 OPERATION 7. Optional Unfi nished: consisting of panels with exposed
A. Operation shall be Individual Panels / Curve & Diverter, acoustical substrate or steel skins for fi eld applied
consisting of Individual Panels that are top supported by two wall covering or painting.
(2) carriers riding through radius Curve and Diverter type
intersections. B. Finish Material Supplier: Finish material shall be (select):
1. Standard Factory Supplied: from manufacturer’s standard
2.04 STACK ARRANGEMENTS selection of fi nish materials, as specifi ed.
A. Stack Type: Panel storage confi guration shall be (select):
2. Optional Customer Supplied: from customer’s selection of
1. Standard Perpendicular Stack: consisting of panels stacking
at a 70 angle perpendicular to the wall’s installed position. fi nish material, by others, and as approved by KWIK-WALL
o
Company.
2. Optional Parallel Stack: consisting of panels stacking at a 20 o
angle parallel to the wall's installed position. (Note: For panel C. Finish Material Application: Finish material shall be (select):
o
fabrication heights over 16'-2" (4.93 m) panels stack at a 20 1. Standard Factory Applied: by KWIK-WALL's authorized
angle parallel to the wall’s installed position.) distributor. Customer supplied fi nish material samples must
3. Optional Remote Stack: consisting of panels stacking at a 20 o be submitted to manufacturer for testing and approval prior
angle located remotely from the wall's installed position, as to acceptance and application.
shown on submitted shop drawings. (Note: For panel
fabrication heights over 16'-2" (4.93 m) panels stack at a 20 2. Optional Field Applied: by others.
o
angle remotely from the wall’s installed position.)
B. Stack Quantity: Panels shall be stored in separate stack areas as
required for panel storage.
2.05 FINISHES
A. Finish Material Type: Panel fi nish material shall be Class A
(except wood veneer) rated in accordance with ASTM E 84,
consisting of (select):
3