Page 256 - Arch binder
P. 256

Operable Partitions   MODEL 3020GL PART 2 - PRODUCT SPECIFICATIONS
                                        10 22 26 (10650)

         2.01 ACCEPTABLE MANUFACTURER                                2. Optional Parallel Stack: consisting of panels stacked
                                                                           parallel to the wall’s installed position.
         A. Operable walls shall be Series 3000, Model 3020GL Individual
         Panels /Multi-Directional as manufactured by KWIK-WALL        3. Optional Remote Stack: consisting of panels located
         Company.                                                           remotely from the wall’s installed position, as shown on
                                                                           submitted shop drawings.
         2.02 PANEL CONSTRUCTION
         A. Panel Dimensions:  Standard panel dimension shall be a nominal   B. Stack Quantity: Panels shall be stored in separate stack areas
              4" [101.6] thick.                                        as required for panel storage.

         B. Panel Frame:  Steel frame shall be 16-gauge galvanneal steel;    2.05 FINISHES
              horizontal top cross member shall be minimum 12-gauge           A. Finish Material Type: Panel fi nish material shall be Class
              galvanneal steel which meets or exceeds ASTM A 653             A (except wood veneer) rated in accordance with ASTM E 84,
              requirements. Frame shall be all-welded construction and shall be      consisting of (select):
              Class A rated, fi re retardant, non-combustible and non-corrosive in        1. Vinyl: consisting of Type II, reinforced vinyl weighing
              accordance with ASTM E 84.  Panel frame shall be designed to             21 oz./lin. yd. (651 g/lin. m). Vinyl shall meet or exceed
              accept two (2) pieces of 1/4" [6.35], thick glass in opening cut out.             CCC-W-408A and CFFA-W-101-D quality standards.
              (Glass opening size will vary based on panel height and width.
              Refer to shop drawings for sizes.)                       2. Optional Upgrade Fabric: consisting of fade and tear
                                                                            resistant fabric that resists water-based stains weighing 13
         C. Panel Skins: Panel skins shall be Class A rated (except Wood              oz./lin. yd.(403 g/lin. m).
              Veneer and High Pressure Laminate) in accordance with ASTM E
              84. Panel skin material shall consist of (select):       3. Optional Basics Carpet: consisting of acoustically
                                                                            absorbent, non-woven needle punch fi bers fused to prevent
              1. Standard Acoustical Substrate: consisting of structural             fraying and unraveling of material weighing 28.5 oz./lin.yd.
                  acoustical substrate pressure laminated to both sides of the            (884 g/lin.m). Basics Carpet shall achieve a minimum NRC
                   steel frame to form a rigid, unitized and structural panel.            rating of .20 (applied over gypsum substrate)  accordance
                                                                            with ASTM C 423.
              2. Optional Steel Skins: consisting of minimum 22-gauge tension-
                  leveled galvanneal steel, pressure laminated to a structural         4. Optional Upgrade Carpet: consisting of acoustically
                  acoustical backer and mechanically fastened to the steel frame             absorbent, non-woven needle punch fi bers fused to
                  to form a rigid, unitized and structural panel.             prevent fraying and unraveling of material weighing 23
                                                                             oz. / lin. yd. (713 g / lin. m). Upgrade Carpet shall achieve a
              3. Optional Wood Veneer: consisting of particle board core covered                 minimum NRC rating of  .25  (applied over gypsum
                  with wood veneer and pressure laminated to both sides of the                substrate) in accordance with ASTM C 423.
                  steel frame to form a rigid, unitized and structural panel.
                                                                       5. Optional Wood Veneer: consisting of unfi nished fl at cut
              4. Optional High Pressure Laminate: consisting of particle board             wood veneer laminated to 1/2" [12.7] thick particle board
                  core covered with general purpose plastic laminate and            core. Veneer shall be book / running matched
                  phenolic backer sheet, which is pressure laminated to both sides            within a panel, and vertically edge banded if Trimless
                  of the steel frame to form a rigid, unitized and structural panel.           astragals are specifi ed.
                                                                  Notes: Optional Class "A" rated particle board is available.
         D. Glass:  Opening cut out in panel shall be glazed with insulated    Acoustical substrate STC ratings apply for Wood Veneer panel
              glass that is manufactured in accordance with ASTM E 2190. Glass      construction.
              type shall be an acoustical insulated glass unit  1  " [44.5] thick        6. Optional High Pressure Laminate: consisting of general
                                                 3/4
              with 1" [25.4] air space  Glass shall be retained in opening cut out             purpose plastic laminate pressure bonded to ½" [12.7]
              using an aluminum extrusion.                                 particle board core, and edge banded if Trimless astragals
         E. Panel Weight: Maximum panel weight shall be                    are specifi ed.
                         2
                                      2
              11.3 - 12.3 lbs./ft.  (55 - 60.5 kg/m ) depending on STC rating,   (Note: Acoustical substrate STC ratings apply for High Pressure
              size and options selected.                          Laminate panel construction.)
         2.03 OPERATION                                               7. Optional Unfi nished: consisting of panels with exposed
                                                                           acoustical substrate or steel skins for fi eld applied
         A. Operation shall be Individual Panels with a Multi-Directional track           wall covering or painting.
                                               o
              system that allows the panels to negotiate 90  “X”, “L” and “T”
              intersections as required for movement of panels from storage  B. Finish Material Supplier: Finish material shall be (select):
              location(s) to various installed positions. Panels shall be top       1. Standard Factory Supplied: from manufacturer’s standard
              supported by two (2) carriers featuring dual horizontal precision           selection of fi nish materials, as specifi ed.
              bearings with high strength polymer tires riding on a structural
              aluminum track.                                          2.Optional Customer Supplied: from customer’s selection of
                                                                           fi nish material, by others, and as approved by KWIK-WALL
                                                                           Company.
         2.04 STACK ARRANGEMENTS
         A. Stack Type: Panel storage confi guration shall be (select):
              1. Standard Perpendicular Stack: consisting of panels stacked
                  perpendicular to the wall’s installed position.


                     Dimensions in [ ] are millimeters. Contact your local distributor for additional assistance or visit www.kwik-wall.com  12-16
   251   252   253   254   255   256   257   258   259   260   261