Page 69 - Arch binder
P. 69

Operable Partitions
                                        10 22 26 (10650)                   MODEL 3020 STACK ARRANGEMENTS











                                                                Standard Perpendicular Stack

             Pocket Width                                       Perpendicular stacking allows individual panels to be located at
                                                                one (1) or both ends and stored perpendicular to the wall’s
                                                                installed position..
            *
            *
                  *
                Stack Depth


              * *  Pocket Width                                 Optional Parallel Stack
                                      Note:
                                      *** If optional double pocket doors w/
                                       expander closure is required minimum   In contrast to perpendicular stacking, Individual Panel
                          *  Stack Depth  dimension is 2’-10" [864].  arrangements may also be stored parallel to the wall’s installed
                              [305] ***                         position, at one (1) or both ends..
                              1’-0"
                         [610]  2’-0"  Min.






                                                                Optional Remote Stack
                                                                For more complex wall system layouts, or when space or other
                                                                room constraints dictate, Individual Panels may be located
            Pocket Width                                        remotely from the wall’s installed position.

           *
           *
                 *
               Stack Depth



      Stack Depth*                                              Pocket Width**
      The overall depth of the stack area, as required for panel storage,   The width of the pocket is determined by the widest panel in the
      is dictated by the total number of panels in the wall system.  wall run. For specifi cation purposes, assume the widest panel is
      KWIK-WALL’s Model 3020 - Steel panels require an average stack   4'-0" (122cm) maximum. Wall systems that utilize Automatic
      depth of 4 / 4" [108] per panel. To determine the stack depth,   type bottom seals will require extra pocket width to allow
              1
      calculate as follows:                                     clearance for the actuator that protrudes from the bottom of
                                                                the lead panel. Pocket width may be calculated as follows:
      Number of Panels x 4 / 4" [108]
                          1
                                                                If Adjustable or Operable Bottom Seals are specifi ed:
                                                                Panel Width + 7" [178]
            *Note:  Additional stack depth is required for wall systems
                                                                        1
                                                                (allows 3 / 2" [89] for hand clearance on each side)
              containing the following type of panels:
                                           3
                      • Expander Panel Closure or Pass Door Panel:  / 4" [19]
                                                                If Automatic Bottom Seals are specifi ed:
                      • Hinged Panel(s) Closure: 4" [102]
                      • Pocket Door(s): 6" [152]                Panel Width + 10" [254]
                                                                (for actuator clearance on one side)
            **Note:  For wall systems that include Pocket Doors, please
                reference KWIK-WALL’s “3000 Series Pocket Doors” brochure
                                                                plus
                for pocket layout dimensions and applications.
                                                                  1
                                                                3 / 2" [89]
                                                                (for hand clearance on one side)
                                                                                                                   8
                    Dimensions in [ ] are millimeters. Contact your local distributor for additional assistance or visit www.kwik-wall.com  04-18
   64   65   66   67   68   69   70   71   72   73   74