Take readings at full load if possible.
NES-WES Confidential and Proprietary
Unit number # Cylinder temp 1 / 2 °C
Engine serial number # Cylinder temp 3 / 4 °C
Engine model number # Cylinder temp 5 / 6 °C
Operating hours # Cylinder temp 7 / 8 °C
MwH # Cylinder temp 9 / 10 °C
Starts # Cylinder temp 11 / 12 °C
Design number # Cylinder temp 13 / 14 °C
Power, electric kW Cylinder temp 15 / 16 °C
Voltage - average V Cylinder temp 17 / 18 °C
Current - average A Cylinder temp 19 / 20 °C
Neutral current A Average cylinder temp °C
Cosh-phi Ind/Kap Exhaust temp before heat ex °C
Excitation voltage V Exhaust temp after heat ex °C
DE generator bearing temp °C Ignition voltage 1 / 2 kV
NDE generator bearing temp °C Ignition voltage 3 / 4 kV
Generator winding temp L1 °C Ignition voltage 5 / 6 kV
Generator winding temp L2 °C Ignition voltage 7 / 8 kV
Generator winding temp L3 °C Ignition voltage 9 / 10 kV
Generator cooling air intake temp °C Ignition voltage 11 / 12 kV
Jacket water temp °C Ignition voltage 13 / 14 kV
Jacket water pressure Bar Ignition voltage 15 / 16 kV
Oil temp °C Ignition voltage 17 / 18 kV
Oil pressure Bar Ignition voltage 19 / 20 kV
Return water temp °C Ignition point min / max °KW
Oil pressure differential Bar Valve noise min / max mV
Oil pressure before oil filter Bar Knock noise min / max mV
Gear box oil temp °C Differential pressure CC filter mbar
Gear box oil pressure Bar I/C differential pressure mbar
Throttle valve position % Exhaust gas back pressure after turbos mbar
Turbo bypass position % Differential pressure SCR / Catalyst mbar
Mixture temp °C Crankcase pressure at dip stick mbar
Boost pressure Bar Water inlet temp exhaust heat ex °C
Gas mixer position % Water outlet temp exhaust heat ex °C
Tec Jet 1 / Tec Jet 2 λ I/C water inlet temp, 1st stage °C
% I/C water outlet temp, 1st stage °C
l/s I/C water inlet temp, 2nd stage °C
mbar I/C water outlet temp, 2nd stage °C
Δ mbar Intake air temp at engine air filter °C
°C Jacket water concentration test Vol./%
Gas pres before step-down reg 1 / 2 mbar Product applied:
Gas pres after step-down reg 1 / 2 mbar I/C water concentration test Vol./%
Gas blending Gas 1 / Gas 3 % Product applied:
CH4 content / Natural Gas % / NG Notes
Pre-chamber differential pressure mbar
Nominal electrical power 50 / 100% kW
O2 value Vol./%
CO value mg/Nm 3
NOX value mg/Nm 3
O2 correction %