Page 5 - East Tracy
P. 5
G F E D LOT 13 C B DATE A
URBAN COEUR BRIDGER KANSAS CITY, MO 64110 ARCHITECT OF RECORD: DRAW ARCHITECTURE + URBAN DESIGN LLC 214 W 21ST ST, SUITE 200 KANSAS CITY, MO 64108 STRUCTURAL ENGINEER: LIA ENGINEERING 4808 LIBERTY STREET KANSAS CITY, MO 64112 KAW VALLEY ENGINEERING 8040 N. OAK TRAFFICWAY KANSAS CITY, MO 64118 EAST TRACY - BEACON HILL OVERLOOK © 2018 DRAW ARCHITECTURE AND URBAN DESIGN LLC ALL DRAWINGS AND WRITTEN INFORMATION APPEARING HEREIN SHALL NOT BE DUPLICATED , DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. ORIGINAL DRAWINGS SCALE TO 24" x 36" SHEET UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION. FLOOR PLANS A100 NOT FOR CONSTRUCTION Printed 10/3/2018 1:14:35 PM
OWNER: 4325 TROOST AVE T 816.457.1756 T 816.531.8303 F 816.531.8305 T 816.534.9542 CIVIL ENGINEER: T 816.468.5858 PRINCIPAL IN CHARGE D DAVISON PROJECT ARCHITECT D DAVISON PROJECT TEAM MEMBERS D HERRON J HARTMAN RELEASE SCHEDULE RELEASE NO.
1 GENERAL NOTES 1. ALL WALL LIGHTING HEIGHTS ARE TO BE COORD. WITH ARCHITECT. 2. ALL EXHAUST FANS ARE TO BE ON A TIMER. 3. LIGHTS IN WET AREAS ARE TO BE DAMP RATED. 4. PROVIDE IC RATED RECESSED LIGHT FIXTURES IN ALL AREAS ADJACENT TO INSULATION. 5. CONTRACTOR TO VERIFY LIGHTING FIXTURE COMPLIANCE WITH IRC, AND/OR ALL CURRENT APPLICABLE LOCAL CODES AND ORDINANCES. 6. MOUNT ALL OUTLETS AT STANDARD MOUNTING HEIGHT PER CODE, UNO. 7. PROVIDE QUANTITY AND SPACING AND ELECTRICAL INSTALLATION PER IBC, IRC, AND/OR ALL CURRENT APPLICABLE LOCAL CODES AND ORDINANCES. CONTRACTOR TO PROVIDE QUANTITY AND LOCATION TO MEET CODE. 8. COORDINATE ELECTIRCAL FIXTURES AND QUANTITIES WITH MECHANICAL OR PLUMBING CONTRACTORS. 9. CENTER FIXTURES IN ROOM, UNO. 10. CONTRACTOR TO VERIFY LUMINAIRE VOLTAGE WITH BRANCH CIRCUIT SUPPLYING POWER TO LUMINAIRE PRIOR TO ORDERING. 11. CONTRACTOR TO DETERMINE ROUGH‐IN HOUSING SPEC IN ORDER TO ENSURE COMPATIBILITY WITH MOUNTING CONDITION. 12. CONTRACTOR TO VERIFY COMPATIBILITY OF TRANSFORMERS FOR ALL LOW VOLTAGE LUMINAIRES WITH DIMMER CONTROLS. 13. CONTRACTOR TO VERIFY ALL FINISH OPTIONS FOR LUMINAIRE TRIMS, REFLECTORS, FLANGES, ETC WITH ARCHITECT. 14. 5/8" TYPE X GYP BD WALLS AND CEILING WITHIN GARAGE SPACE PER R302.6 1
TO A100
2 MOVE WALL DIMS FROM STRUCTURAL 2
3 0' ‐ 6" 11' ‐ 10" 24' ‐ 8" 11' ‐ 10" 0' ‐ 6" 3
1' ‐ 8 3/4" 19
4 4
GARAGE DOOR TO COMPLY WITH XXX
25' ‐ 1" GARAGE 25' ‐ 1"
WALL SLOPES DOWNWARD WITH STAIR PLUMB WALL
HANDRAIL
5 5
A10 A300 DN R @ 0' - 6 21/32" 9 A10 A300
1' ‐ 11 3/4" 2' ‐ 11 1/4"
17
FURN 18 16 RR 1 A 4' ‐ 9 1/2" 4' ‐ 5 1/4"
A400 MUD RM D 3x5 C5 11' ‐ 10 1/4"
C3 15 A400 C8 A400 M. BATH 11 A
1' ‐ 10 1/4" M. BEDROOM 2' ‐ 5 1/2"
15' ‐ 3" REF. 12 12' ‐ 4 1/2" A
6 13' ‐ 11 1/4" 11' ‐ 11" 11' ‐ 5 1/4" 6
A5 14 PANTRY M. CL 5' ‐ 11"
A3 A400 A8 KITCHEN
A10 TV 10
DW
HANDRAIL 07 09 WH
GFI A
D B 06
A201 A8 6' ‐ 11 1/4" DN A201 A8 CL 3 W A8 A200
39' ‐ 0" 36" HIGH RAILING 6' ‐ 5 3/4" 39' ‐ 0" 12' ‐ 5 1/4" BEDROOM 3 08
7 12' ‐ 9 3/4" D 7
B 10' ‐ 0" 29' ‐ 9 1/2"
D
4' ‐ 5 1/2" TV 05 A400 6 21/32"
11' ‐ 6 1/4" TV LIVING ROOM DINING ROOM 6 21/32" D 4' ‐ 5 1/2" A TV RR 2 C10 R @ 0' - 18
R @ 0' - 04 VENT, PAINT TO MATCH
18 D 12' ‐ 5 1/4" BEDROOM 2 LOW PROFILE DRYER SURROUNDING WALL
11' ‐ 4 1/4"
8 8
B 7' ‐ 8 1/4" CL 2
A6 A300 5' ‐ 3 1/2" A6 A300 03 02 UP
2' ‐ 3 3/4"
B
D D 13 C 01
4' ‐ 8 1/2" 4' ‐ 8 1/2" DN 5' ‐ 0" 7 3/8"
R @ 0' -
13
9 9
DN
4' ‐ 5 1/2"
4' ‐ 9"
5' ‐ 11 1/4"
9' ‐ 6"
‐‐‐ ‐‐‐
‐ 4' ‐ 9" 13' ‐ 11 1/2" ‐ 5' ‐ 11 1/4"
A10 A301 D10 A300 LOT 14 A10 A301 24' ‐ 8" D10 A300 LOT 12
SECOND FLOOR 1/4" = 1'‐0" FIRST FLOOR 1/4" = 1'‐0"
D5 RE: A8/A200 D5 RE: A8/A200
A200 A200 5' ‐ 0"
10 10
D10 A10
G F E D C B A