Typical Wiring
       Modules will accept #18 AWG (0.75mm ), #16 (1.0mm ), #14 AWG (1.50mm ) and #12 AWG (2.50mm ) wire sizes.
                                                                   2
                                                                                       2
                                      2
                                                  2
       Note: Sizes #16 AWG (1.0mm ) and #18 AWG (0.75mm ) are preferred for ease of installation. See Signature Loop Controller catalog
                               2
                                                   2
       sheet for detailed wiring requirement specifications.
                                               AB4G            AB4G            AB4G
                                            Audible Base     Audible Base    Audible Base
                                                                                                      6254A-003
                                                                                                      EOL Relay
          Listed 24 VDC  + +
         Nominal Power       1                                                                            2
                Supply  - -
                          1
                                                        2                2              2
                                                                                                     2
                                   1        2
                                                         3                3
                                                                                                 CT1
                             CR         CRR        3          GSA-CRR


                                                                                      3
            Signature  + +
            Controller  DATA  -  3  3  Optional CR
                                       for disabling/disconnecting
                                       sounder base
                                                                                      GSA-MCRR
        GSA-CRR Schematic          GSA-MCRR Schematic
           SIGA-CRR Schematic
                                      Power In Power Out                                              6254A-003
                                                 Polarity reverses
                                                 when activated.                                 1  11  EOL Relay
                                                                         Audible         DATA (+) IN/OUT  required for
                                                                          Bases      DATA (-) OUT  DATA (-) IN  2  10  supevision
                                                                                 SIG +  SIG -    3  4  9  8
                                                                                                   7
                                                                                                   6
                                                                                                   5



                                                                         7                              8  7
                                                       Signature
        Notes                                          Data  Data Out
                                                       Circuit
          1  Refer to the Signature controller installation sheet for                  For normal operation  CT1
           wiring.                                                        8            For General Fire
                                                                                       Alarm Operation
          2  One Pair of Wires (24 Vdc power).           UL/ULC Listed                                  4  3 2 1

                                                         24 Vdc power
          3  One Pair of Wires (Signature Data).         supply            or

          4  Single Wire (24 Vdc power).                                12 34  12 34

          5  The GSA-UIO6R and the GSA-UIO2R do not come                                    MCRR
           with TB14.                                      7  1                             UIO(R) series motherboard
          6  The GSA-UIO6 does not come with TB8 through   Data Out                      4 3
           TB13.                                                                         2     No connections required for
                                                     Signature  4                        1  5  MCRR. Other modules may
          7  Supervised and power-limited.           Data     3 2                      TB14    require connections.

                                                     Circuit
          8  If the source is nonpower-limited, maintain a space   1  TB7
           of 1/4 inch from power-limited wiring or use FPL,                473387360  473387359
           FPLP, FPLR, or an equivalent in accordance with the   Data In  CAT NO.  MCRR  CAT NO.  MCRR  4  Green LED (Normal)
           National Electrical Code.                                                     3            Red LED (Active)
                                                                                         2
          9  Maximum #12 AWG (2.5 mm² ) wire; Minimum  #18                               1     No connections required for
           AWG (0.75 mm² ).                       Green LED (Normal)                   TB15    MCRR. Other modules may
         10  End-of-Line Relay must monitor and report power   Red LED (Active)  1 2 3 4  1 2 3 4  require connections.
           supply trouble to control panel.                              6      6
         11  Class B Data wiring may be “T-tapped.”  Optional MCRR
                                                 or MCR for        No connections required for MCRR. Other
                                                 disabling/disconnecting
                                                 an audible base.  modules may require connections.