                                Cycle Report
              TCB Name      TCB_Olympiada
              TCB Serial Number    20154010
              Teramon Software Version     Version :0.9.3.203
              Cycle Number    00002193
              Date          27/04/2015 08:00:03
                               Sensor: TM50-1
              Start time: 08:00:03
              Serial Number: 369470 - Factory Name: TM50
              Initial Position validation method: Resection
                             Initial Position Measurements
               Point  Face  H. Angle  V.Angle  Slope Distance
              ACN-
              3D-R2  I    263.28472  96.54182   136.54063
              ACN-3D-R2   II  63.28394  303.45811  136.54143
              ACN-3D-R3  I  269.43222  96.52066  143.49059
              ACN-3D-R3  II  69.43170  303.47876  143.49079
              ACN-3D-R4  I  267.38655  96.61848  139.54656
              ACN-3D-R4  II  67.38637  303.38099  139.54716
              ACN-3D-R5  I  29.06206  102.00468  63.31563
              ACN-3D-R5  II  229.06196  297.99566  63.31543
              ACN-3D-R6  I  62.75090  101.94169  60.66450
              ACN-3D-R6  II  262.75085  298.05816  60.66430
              ACN-3D-R7   I  94.60460  101.40169  76.20883
              ACN-3D-R7   II  294.60424  298.59807  76.20873
                           Initial Position Measurements Averages
               Point     H.Angle     V.Angle   Slope distance
               ACN-      -1.00000    -1.00000   -0.99999
               3D-R3
              ACN-3D-R2  263.28433   96.54185   136.53967
              ACN-3D-R3  269.43196   96.52095   143.48926
              ACN-3D-R4  267.38646   96.61874   139.54546
              ACN-3D-R5  29.06201    102.00451   63.31489
              ACN-3D-R6  62.75088    101.94176  60.66380
              ACN-3D-R7  94.60442    101.40181  76.20802
                                                                                                 Gold Line Doha Qatar
            1. MONITORING SOLUTIONS


            b. AMS - TCB







            A fully automated data collect solution for real time monitoring
            using Total stations and/or GPS.


            SYSTEM ADVANTAGES                                               Athens metro line            TCB internal
            •    Portability
            •    Operation with solar panel in areas without electric power
            •    Remote control using android application for power on–power off
              system.
            •    Real time alerts using SMS/mail
            •    4g/3g Internet connection and optional dual SIM kit
            •    Full report on each cycle of measurements
            •    Direct communication with Terramove Database
            •    Resection solution with lowest number of squares for instrument
              position check.
            •    Automatic calculation of measurement corrections on each
              cycle
            •    Automatic calculation of measurement corrections  on each cycle                Kassandra gold mines





             4