Page 196 - IGC BOOK
P. 196

Control Measures for Powered Forklift Trucks


               Diesel powered trucks

               •  Operated in a well-ventilated area.
               •  Storage limited to minimum quantity.
               •  Keep suitable fire extinguishers in the storage area.

               •  Turnoff engine before re-fuelling.

               •  Spill procedures must be developed, Spills must be cleaned immediately.
               •  Use PPE, gloves, goggles while handling diesel.

               Battery powered trucks

               •  Charge batteries in a well-ventilated area to dissipate heat.

               •  When charging batteries, keep the battery vent caps in place to prevent electrolyte spray.
               •  wear safety glasses and a face shield for protection against electrolyte splash or spray.

               •  charging station must be equipped with a hoist to avoid manual handling risk.
               •  No smoking or performing activities which may produce source of ignition.

               •  Use suitable PPE insulated gloves, shoes to avoid electrocution.

               Liquified Petroleum Gas

               •  Operated in well-ventilated area.
               •  Check for any leaks prior to start operation.

               •  LPG cylinders become cold during operation, use gloves while changing cylinders.
               •  Suitable fire extinguisher must be fitted to the forklift.

               •  Use hoists to lift cylinders to avoid manual handling risk.
               •  Provide well-ventilated storage facility for LPG cylinders.






























                 POSHE V2 |                                                                                                                                        Unit IG2 – Element 6 – Musculoskeletal   20
                  Health
   191   192   193   194   195   196   197   198   199   200   201