                                            ASME A112.19.8-2007 has been replaced by ANSI/APSP-16
                                            2011. ANTIENTRAPMENT protection EQUIPMENT (covers,
                                            SUCTION FITTINGS, safety vacuum release system—SVRS**,
                                            etc.) must comply with ASME A112.19.8-2007—or any successor
                                            standards—whether the EQUIPMENT is manufactured or field
                                            fabricated.


                              6.8.1.2.3     Temperature (10)
                                            A temperature-control mechanism to prevent the temperature from
                                            exceeding 40°C (104°F) must be provided on WHIRLPOOL SPAS
                                            and SPA POOLS. The water temperature must be measured within
                                            the WHIRLPOOL SPA or SPA POOL tub itself.

                   6.9        RWF Showers and Toilet Facilities
                              Vessels constructed to the 2018 Construction Guidelines or later must have toilets
                              and showers installed.

                       6.9.1   Temperature and Location
                               Showers must provide POTABLE WATER at a temperature not to exceed 43°C
                               (110°F) during normal operations. Showers must be installed within 10 meters
                               (33 feet) of every entry point to each RWF. For beach entry RWFs, a minimum
                               of one showerhead must be installed per 10 meters (33 feet) of perimeter within
                               10 meters (33 feet) of the beach perimeter. A minimum of one shower must be
                               installed at each water slide staircase entrance.

                       6.9.2    Showers for Children
                               RWFs designed for use by children under 6 years of age must have appropriately
                               sized shower facilities. Standard height is acceptable, but the mechanism to
                               operate the flow of water must not be more than 1 meter above the deck.

                       6.9.3    Toilet Facilities
                               Toilet facilities must be located within one fire zone (approximately 48 meters
                               [157 feet]) of each RWF and on the same deck or adjacent decks if there is no
                               obstruction between RWF area and entrances to the toilets. If toilets are not
                               located on the same deck they must be easily visible and ACCESSIBLE from
                               the RWF area. A minimum of two separate toilet rooms (either two unisex or
                               one male and one female) must be installed. Each toilet facility must include a
                               toilet and a handwashing facility. Urinals may be installed in addition to the required
                               toilet, but may not replace the toilet.

                   6.10       Restrictions


                       6.10.1  Diapers (10)
                               Children in diapers or who are not toilet trained must be prohibited from using
                               any RWF not specifically designed and APPROVED for use by children in
                               diapers.