                          Seam: An open juncture greater than 0.8 millimeters (1/32 inch) but less than
                          3 millimeters (1/8 inch).

                          Smooth:
                                 •  A FOOD-CONTACT SURFACE having a surface free of pits and
                                     inclusions with a cleanability equal to or exceeding that of (100-grit)
                                     number 3 stainless steel.
                                 •  A NONFOOD-CONTACT SURFACE of EQUIPMENT having a surface
                                     equal to  that of commercial grade hot-rolled steel free of visible scale.
                                 •  Deck, BULKHEAD, or DECKHEAD that has an even or level surface
                                     with no roughness or projections to make it difficult to clean.

                          Spa pool: A POTABLE WATER or saltwater-supplied pool with temperatures and
                          turbulence comparable to a WHIRLPOOL SPA.
                                 •  Depth of more than 1 meter (3 feet) and
                                 •  Tub volume of more than 6 tons of water.

                          Spill-resistant vacuum breaker (SVB): A specific modification to a PRESSURE
                          VACUUM BREAKER ASSEMBLY to minimize water spillage.

                          Spray pad: Play and water contact area designed to have no standing water.

                          Suction fitting: A fitting in a RECREATIONAL WATER FACILITY under direct
                          suction through which water is drawn by a pump.

                          Swimming pool: A RECREATIONAL WATER FACILITY greater than 1 meter in
                          depth. This does not include SPA POOLS that meet this depth.

                          Technical water: Water that has not been chlorinated or pH controlled on board  the
                          vessel and that originates from a bunkering or condensate collection process,  or
                          seawater processed through the evaporators or reverse osmosis plant and is  intended
                          for storage and use in the technical water system.

                          Temperature-measuring device (TMD): A thermometer, thermocouple,
                          thermistor, or other device that indicates the temperature of FOOD, air, or water and
                          is numerically scaled in Celsius and/or Fahrenheit.

                          Turnover: The circulation, through the recirculation system, of a quantity of  water
                          equal to the pool volume.

                          Unblockable drain/suction fitting: A drain or SUCTION FITTING in a
                          RECREATIONAL WATER FACILITY that cannot be completely covered or
                          blocked by a 457 millimeters x 584 millimeters (18 inches x 23 inches) body-
                          blocking element and that is rated by the test procedures or by the appropriate
                          calculation in accordance with ASME A112.19.8M.