WMX101-168/104-168 (IP68 Housing)
IP68 L H T ID Shipping Weight
WMX IP68 Version
inch mm
Meter Size inch mm i nch mm inch mm pounds Kg
6.80 173
3” 12.0 305 8.12 206 .68 17.3 2.60 66.04 41 19
9.22 234
4” 10.24 260 1 0.22 260 .62 20.9 3.12 79.25 35 16
6” 12.27 312 11.22 285 .69 23.3 5.05 128.27 50 23
12.28 312
8” 14.24 362 .69 23.3 6.44 163.58 72 33
10” 18.18 462 .69 23.3 8.61 218.69 128 58
†12” 19.68 500 .81 20.6 10.55 267.97 148 67
Flanges Standard ANSI 150 lb. drilling Cable (WMX 101) 1 lb.
†IP68 available for WMX104-1200 only. IP68 is not available for WMX101-1200.
WMX101/104 (Standard Housing)
Standard L H T ID Shipping Weight
WMX Standard
Meter Size inch mm inch mm
inch mm inch mm pounds Kg
4” 10.24 260 7.0 178 .62 20.9 3.12 79.25 32 15
6” 12.27 312 8.1 206 .69 23.3 5.05 128.27 47 21
8” 14.24 362 9.1 231 .69 23.3 6.44 163.58 69 31
10” 18.18 462 10.1 257 .69 23.3 8.61 218.69 125 57
12” 19.68 500 11.1 282 .81 20.6 10.55 267.97 145 66
Flanges Standard ANSI 150 lb. drilling Cable (WMX 101) 1 lb.
ORDERING INFORMATION
MODEL SIZE OPTIONS FLOW MEASUREMENT UNITS
External power = WMX101 3” = -300* High Frequency = -HF RATE ORDER TOTAL ORDER
Battery power = WMX104 4” = -400 10 Units**/Pulse = -PxX
6” = -600 100 Units**/Pulse = -PxH Gal/Min = GPM Gal = G
8” = -800 1000 Units**/Pulse = -PxK Liter/Min = LPM Gal x 1000 = GT
10” = -1000 Factory Installed Power Cable Liters/Sec = LPS Liter = L
12” = -1200 6m (20 ft) = -11/6 Cu Ft/Min = CFM Liter x 1000 = LT
Factory Installed Power Cable Cu Meter/Hr = CMH Mega Liters = ML
15m (50 ft) = -11/16 Mil Gal/Day = MGD Cubic Meters = CM
Meg Lit/Day = MLD Cu Met x 1000 = CMT
Internal Data Logger = -127 Cubic Feet = CF
IP68 Submersible = -168† Cu Feet x 1000 = CFT
†IP68 available for WMX104-1200 only *-300 is IP68 only **Units = Gal or Liter depending Consult factory for additional units
IP68 is not available for WMX101-1200 on Rate/Total unit selection Any rate selection can be combined with any total selection
ACCESSORIES Post-Factory 20-ft. Power/Output Cable Grounding Rings
(WMX104 Standard Housing Only) = DC30 (not needed for most applications):
Remote 4-20 mA (analog) signal = AO55W
Post-Factory 50-ft. Power/Output Cable 3” = 102157 8” = 100878
Remote Rate and Total Indicator (Battery) = FT450 (WMX104 Standard Housing Only) = DC35
4” = 100876 10” = 100879
Remote Rate and Total Indicator (Powered) = FT400 Series Post-Factory 100-ft. Power/Output Cable
(WMX104 Standard Housing Only) = DC100 6” = 100877 12” = 103288
Remote Data Logger = DL76W
Post-Factory 20-ft. Power/Output Cable
Dual Power Supply, 115 Vac, 12/24 Vdc = PC42 (WMX104 IP68 Housing Only) = DC30S
(Use with High Frequency pulse rate)
Post-Factory 50-ft. Power/Output Cable
Replacement Battery Pack for WMX101 = 101317 (WMX104 IP68 Housing Only) = DC35S
Replacement Battery Pack for WMX104 = 100889
Post-Factory 100-ft. Power/Output Cable
(WMX104 IP68 Housing Only) = DC100S