10    HIGH PRESSURE HYDROSTATICS | HPR-02 SELF-REGULATING PUMPS











                                          HPR-02                    55  75  105  135  165  210  105D  280  125D  165D
                                          Max. displacement  cc/rev  55  75.9  105  135.7  165.6  210.1  210  281.9  252  331.2
                                          Continuous rated speed  rpm  2700  2500  2350  2300  2100  2000  2350  1800  2300  2100
                                          w/o pressurizing
                                          Max. oil flow     l/min  148.5  189.8  246.8  312.1  347.8  420.2  493.5  507.4  579.6  695.5
                                          Nominal pressure  bar    420  420  420  420  420  420  420  420  350  420
                                          Peak pressure (intermittent)  bar  500  500  500  500  500  500  500  500  420  500
                                          Continuous input torque  Nm  219  302  418  540  659  836  836  1122  1003  1318
                                          Max. input torque  Nm    368  507  702  907  1107  1404  1245  1884  1404  1964
                                          Continuous power  kW    61.9  79.1  102.8  130.0  144.9  175.1  205.6  211.4  241.5  289.8
                                          Max. power        kW     104  132.8  172.7  218.5  243.4  294.1  306.7  355.2  338.1  431.8
                                          Weight (approx.)  kg      39  39   50   65   89  116  96   165  113  177








          HPR-02.

          Self-regulating pumps for open circuit operation.





          Design characteristics                              Controller types

          —   axial piston pump in swashplate design for high pressure  —   LP    load sensing with pressure cut-off
             open circuit systems                             —   H1L   load sensing with hydraulic ∆pLS – override
          —   clockwise or counter clockwise rotation         —   E1L    load sensing with electrical ∆pLS – override
          —   self-priming at high nominal speed              —   LEP    load sensing with electric stroke limiter
          —   tank pressurization or swash angle reduction for         and pressure cut-off
             high speed applications                          —   ETP    electro-proportional with hyperbolic power-
          —   adaptive noise optimization SPU                          limiter and pressure cut-off
          —   decompression fluid is discharged via pump housing to  —   TL2   load sensing with hyperbolic power limiter
             keep suction side calm
          —   exact and robust load sensing controllers with  Product advantages
             or without swash plate position feedback
                                                              —   optimum interaction with Linde LSC control valves
                                                                 and LinTronic
                                                              —   energy saving operation by ‘flow on demand’-control
                                                              —   dynamic response
                                                              —   excellent suction up to rated speed
                                                              —   noise optimization over the whole range of operation
                                                              —   compact design
                                                              —   high power density
                                                              —   high reliability