Page 73 - Tubelite Electrical Catalog
P. 73

CALL 800 -505 - 4900      F AX 800 -505 - 7 454



                                                                ELECTRONIC SIGN BALLASTS









        signPRO  Electronic Sign Ballast                                                                              BALLASTS
                      ®

        For T12/HO Rapid Start Fluorescent Lamps
                  ®
        Each signPRO   electronic  ballast  utilizes  the  very  same  steel  housing  as  their  magnetic
        counterparts, and uses the same wiring configurations. This makes replacing old magnetic
        ballasts  a  snap!  For  those  users  looking  to  reduce  their  energy  bills  at  every  corner,
        signPRO electronic  sign  ballasts  offer  the  solution  –  energy  savings  of  up  to  20%

        when compared to magnetic sign ballasts.
             u Underwriters Laboratories (UL) listed (Class P, Type 2 Outdoor) and CSA Certified
             u Operate at a nominal line voltage of 120V +/- 10%, 60Hz
             u Have a power factor greater than 98% at max. load
             u 3 year warranty with a 90°C maximum case temperature


        signPRO Electronic Sign Ballast - T12/HO Rapid Start


                               Lamp Data                       Max
                                                Min.           Line         Open
           Item                   Lamp Footage  Starting   Input   Cur-  Watts  Circuit   Dim.  Wiring   Weight
                           No. of               Temp.   Volts  rent          Volts          Diag.   (lbs.)
                           Lamps   Min   Max                  (Amps)
           AD3ASB041612E    1,2     4    16     -20°F   120    1.46   175    750    BL-1    21, 39   6
           AD3ASB12322E    2,3,4   12 l  32 l   -20°F   120    2.95   350    1000   BL-2   5,9,13    8
           AD3ASB204846E*  4,5,6   20 q  48 q   -20°F   120    4.17   490    1000   BL-3  14,15,19   10
         *Operates (3) 10ft. lamps - use wiring diagram 28.
               l  Total lamp length of each circuit (A) and (B) must not be less than 6 ft. nor more than 16 ft.
                   Circuit (A) is comprised of lamps 1,2. Circuit (B) is comprised of lamps 3,4.
               q Total lamp length of each circuit (A) and (B) must not be less than 10 ft. nor more than 24 ft.
                   Circuit (A) is comprised of lamps 1,2,3. Circuit (B) is comprised of lamps 4,5,6.



         Ballast Dimensions

              Designation      Length (L)  Width (W)   Height (H)  Mounting (M)
                                                                                                C
                 BL-1           11.703”     3.187”       1.75”     11.140”       H
                 BL-2           11.703”     3.187”      2.671”     11.140”
                 BL-3           14.312”     3.187”      2.671”      13.75”         W                   M L