Page 2 - Seismic Cabinets
P. 2

File Number: MC1509                    Issued: February 5, 2002
Project Number: 02RT3038                              Page 2 of 31
Model Number: Cabinet Series 2000-SUK

Project Handler:                       Reviewed By:

Michelle Henderson                     Arnold C. Sheldon
Associate Project Engineer             Engineering Team Leader
NEBS Services                          NEBS Services
Conformity Assessment Services         Conformity Assessment Services

This Document was prepared by:

                   Underwriters Laboratories, Inc.
                   12 Laboratory Drive
                   Research Triangle Park, NC 27709
                   (919) 549-1400

Copyright © 2002 Underwriters Laboratories, Inc.

All Rights Reserved

      Underwriters Laboratories Inc. reports apply only to the specific samples tested under stated test
      conditions. It is the manufacturer's responsibility to assure that additional production units of this
      model are manufactured with identical electrical and mechanical components. Underwriters
      Laboratories Inc. shall have no liability for any deductions, inferences, or generalizations drawn by
      the client or others from Underwriters Laboratories Inc. issued reports.
      This report is the confidential property of the client. As a mutual protection to our clients, the
      public, and ourselves, extracts from the test report shall not be reproduced except in full without
      UL’s written approval. This report shall not be used, by the client, to claim product endorsement by
      NVLAP or any agency of the US government.

®

      Underwriters Laboratories, Inc. Bellcore GR-63-CORE Earthquake Zone 4 Test Report