Page 173 - FanPedia - By Twin City Fan and Blower
P. 173
FAN-PEDIA SPECIAL CONSTRUCTION
Published by
Twin City Fan & Blower HIGH TEMPERATURE
©2017 TCF.COM
CENTRIFUGAL FANS (Pedestal Types) GENERAL INFORMATION
Industrial processes often require high heat
Motor Heat Shield Insulation Insulation Pins Pedestal Spacer fans that can withstand operating airstream
temperatures ranging from 276 F to 1,000+ F.
o
o
High temperature fans are commonly used for:
• Re-circulating air in high temperature
equipment such as kilns, dryers, industrial
ovens and furnaces
• Exhausting gases and fumes from industrial
processes
• Supplying air for heating and drying systems
TCF packages:
• 301 F - 500 F
o
o
• 501 F - 600 F
o
o
o
o
• 601 F - 800 F
• 801 F - 1,000 F
o
o
Pedestal w/Motor Heat Shield Pedestal w/Insulated Panel Pedestal w/Motor Heat Shield • 1,001 F & over (requires Engineering review)
o
o
o
Arrangement 10 (up to 600 F) Arrangement 10 (up to 600 F) Arrangement 9* (up to 600 F)
o
*multiple variations of arr. 9 High Temp Materials
• Mild Steel & Corten
• Stainless Steel
Bearing Requirements
• Use High Temp Grease
• Use Fixed & Floating Bearings
> Refer to bearing basics section
Pedestal w/Insulated Back Separated Pedestal Design
Arrangements 1, 8, 9F (601 F to 800 F) Arrangement 1 & 8 (801 F and above)
o
o
o
NOTE: Provides up to a 3” gap between the
housing and pedestal
87