Page 8 - Power Brochure Final 11-2019
P. 8

Silenced Generators





                                            20 kVA Silenced Generator

                                             Standby   Prime   Fuel Tank    Fuel (L/H)  dBA    Size      Wet
                                              Power    Power   Capacity  Consumption @   @    L x W x H  Weight
                                               kVA      kVA             50%     75%    100%  7m  (mm)    (kg)
                                                                                               1500
                                                22      20       75     2.70  4.05  5.40  65    800      700
                                                                                               1250






                                            40 kVA Silenced Generator

                                             Standby   Prime   Fuel Tank    Fuel (L/H)    dBA   Size     Wet
                                              Power    Power   Capacity   Consumption @    @   L x W x H  Weight
                                               kVA      kVA              50%     75%    100%  7m  (mm)   (kg)
                                                                                                2300
                                                45      40       185    5.95  8.92  11.90  67   1130     1285
                                                                                                1580






                                            60 kVA Silenced Generator

                                             Standby   Prime   Fuel Tank    Fuel (L/H)    dBA   Size     Wet
                                              Power    Power   Capacity   Consumption @    @   L x W x H  Weight
                                               kVA      kVA              50%     75%    100%  7m  (mm)   (kg)
                                                                                                2300
                                                66      60       185    7.28  10.92  14.56  67  1130     1385
                                                                                                1700






                                            100 kVA Silenced Generator

                                             Standby   Prime   Fuel Tank    Fuel (L/H)    dBA    Size     Wet
                                              Power    Power   Capacity   Consumption @    @   L x W x H  Weight
                                               kVA      kVA              50%     75%    100%  7m  (mm)   (kg)
                                                                                                2580
                                               110      100      185    11.40  17.10  22.80  66  1130    1835
                                                                                                1640
                                                            9