Page 113 - Stedall Vehicle Fittings Ltd Catalogue V13
P. 113
Central Locking
Central locking Example Layout
Electrical Locking System (Electrical Diagram 24 Volts)
red 1 A + Electric Feed 24v
black
Remote Control 66197
Ground
Receiving antenna wire
pink
brown
Push button for manual opening 66907
Warning Light 65527
grey yellow
Electric Station 66197 Ground
black Central Control 66227 Central Control 66227 black
Ground Ground
orange 30 A violet brown 30A orange
+ Electric Feed 24v + Electric Feed 24v
violet violet
black black
Handle 69387
Actuator 66207 brown brown
Ground
brown brown
violet violet
red 2 A 2 A red
blue blue
Actuator 66217
red 2 A 2 A red
blue blue
red 2 A 2 A red
blue blue
red 2 A 2 A red
blue blue
Actuator - technical features Remote Control - technical features Central Control - technical features
Rated voltage: 24 V DC. Rated input: 22 -25V Rated input: 22 - 25 V
Pressure force: 30 N. Electrical input (module off: 4 mA) Current max relay (continuous: 15 Amp.)
Max absorbed current: 2.5 A. Electrical input (module on: 4 mA) Opening - closing: manual
Working stroke: 15 mm. Remote control distance: 10 mts Action timing: 0.75 sec.
Operating time: 0.5 sec. Operating temperature: -25°C / +80°C Operating temperature: -25°C / +80°C
Operating temperature: -25°C / +80°C Max external dimensions: 72x88x30 mm
Dimensions: 55x58x91mm.
+44 (0)1454 319524 sales@stedall.co.uk www.stedall.co.uk 85