Important note: This flowchart only applies to standard ABB motors
Type testing means thermistor relays are not mandatory but to allow protection against stall
conditions they are recommended for a safe installation. Use ATEX approved thermistor measurement.
ACS880/ACS580 do not require a contactor as the ATEX approved STO can be used to disconnect.
ACS880/ACS580 do not require an external PTC relay, as an internal option can be used.
ABB drive, 3
without DTC
If the motor voltage is ≤ 500 V
Check the frame size:
Ex nA
ABB drive without DTC Additional testing required
Up to IEC 250... ...a standard motor is ok
to obtain EC Declaration
of Conformity
motor ...insulated non-drive end
IEC 280 to 315... Ex p
needs bearings
ABB drive
motor ...insulated non-drive end with DTC
needs bearings Ex d Please check motor load Motor to be equipped
IEC 355 and above... ...common mode fi ltering Ex de capacity curves to ensure with thermal control to
AC drive installed EC Declaration of Conformity
needs correct dimensioning of ensure Ex-temperature
Ex tD/DIP the motor class
ABB machinery drive,
ACS355
If the motor voltage is 500 to 600 V
+
Motor needs reinforced AC drive needs du/dt
winding insulation OR filtering fi tted Ex nA
In addition, check the frame size. Please check motor load
...if a du/dt fi lter is selected Ex d capacity curves to ensure EC Declaration of Conformity
Up to IEC 250... for the drive (as above) a Ex de correct dimensioning of
standard motor is ok
the motor
IEC 280 to 315... motor ...insulated non-drive end Ex tD/DIP
needs bearings
ABB general ABB general
motor ...insulated non-drive end purpose drive, purpose drive,
needs bearings ACS550 ACS580
IEC 355 and above... *Check with ABB
AC drive ...common mode fi ltering regarding ATEX
availability
installed
needs
If the motor voltage is 600 to 690 V ABB industrial drive, ACS880 with DTC
DriveSize
Using this tool, users can select
Motor needs reinforced AND AC drive needs du/dt Ex nA
winding insulation filtering fi tted a suitable combination of motor
and drive.
In addition, check the frame size. The tool also shows combinations
Ex p that have not been tested.
...if a du/dt fi lter is selected
Up to IEC 250... for the drive (as above) a EC Declaration of Conformity
standard motor is ok Website
Ex d +
motor ...insulated non-drive end Ex de Contains all relevant
IEC 280 to 315... needs bearings certificates for tested drive and
motor combinations.
motor ...insulated non-drive end Ex tD/DIP
needs bearings Combine ATEX approved STO with www.abb.com/drives
eATEX appproved S
IEC 355 and above... FPTC-02 to form a compliant installation www.abb.com/motors&generators
AC drive ...common mode fi ltering that can be installed onto a wall.
needs installed No contactor, no external relays