Page 71 - DMcatalogue2017
P. 71

Low voltage AC drives

         Other variants

         ACS800 – Common user interfaces







         Control panel                                         Typical I/O and control connections
         The control panel features a                          The ABB industrial drive family uses the same control card,
         full-text multilingual display.                       keypad and software structure throughout its entire range.
         Dedicated keys allow fast                             Analogue and digital I/O channels are used for different
         access to actual signals,                             functions such as control, monitoring and measurement
         parameters, assistant functions                       purposes (e.g. motor temperature). In addition, optional I/O
         and drive information. The panel                      extension modules are available providing additional analogue   4
         can be used for parameter                             or digital I/O connections.
         copying and for configuring
         adaptive programmes, working                          Below are the standard drive control I/O of the ABB industrial
         as a PLC inside the drive. Local                      drive with factory macro. For other ACS800 application
         motor control and parameter                           macros the functions may be different. Please refer to the
         copying is also possible.                             firmware manual for details.

                                                                          X20
         Panel mounting kits                                              1   VREF-  Reference voltage -10 VDC,
         Kits are available that allow                                    2   AGND  R L > 1 kohm
         mounting on the cabinet door,                                    X21
         or in a holder inside the cabinet.                               1 2  VREF+  Reference voltage 10 VDC,
                                                                                   R L > 1 kohm
                                                                              AGND
         The panel can be screwed to                                      3   AI1+  Speed reference 0(2) ... 10 V, R in  >
         the cabinet door, without the                                    4   AI1-  200 kohm
         need for an additional holder.                                   5   AI2+  By default, not in use. 0(4) ... 20 mA,
                                                                          6   AI2-  R in  = 100 ohm
                                                                          7   AI3+  By default, not in use. 0(4) ... 20 mA,
         Fieldbus                                                         8   AI3-  R in  = 100 ohm
         The ACS800 supports an                                  rpm      9   AO1+  Motor speed 0(4)...20 mA = 0...motor
                                                                                                  ^
         extensive list of fieldbus                                       10  AO1-  nom. speed, R L < 700 ohm
                                                                                                    ^
                                                                 A        11  AO2+  Output current 0(4)...20 mA = 0...motor
         modules for connectivity to                                      12  AO2-  nom. current, R L < 700 ohm
         industrial networks.                                             X22
                                                                          1   DI1  Stop/Start
                                                                          2   DI2  Forward/Reverse
         I/O expansion                                                    3   DI3
         ACS800 can be fitted with a                                      4   DI4  By default, not in use.
                                                                                   Acceleration & deceleration select
         large range of analogue and                                      5   DI5  Constant speed select
         digital I/O modules to expand its                                6   DI6  Constant speed select
         I/O capability.                                                  7 8  +24VD  +24 V DC max. 100 mA
                                                                              +24VD
                                                                          9        Digital ground
         DriveWindow - PC Tool                                            10       Digital ground
         DriveWindow is a high                                            11       Start interlock (0 = stop)
                                                                                   Power supply
                                                                          X23
         specification, high speed                                        1        Auxiliary power supply output, non-isola-
         commissioning, maintenance                                       2        ted,   24 V DC 250 mA
         and monitoring tool for the                                      X25
         ACS800 drive range. It operates                                  1 2         Relay output 1: ready
         over an optical fibre link. (Drive                               3
         requires an RCDO module)                                         X26
                                                                          1           Relay output 2: running
                                                                          2
         DriveAP - PC Tool                                                3
         DriveAP allows access to the                                     X27
         ACS800 adaptive, block                                           1           Relay output 3: fault (-1)
         programming environment.                                         2
                                                                          3





                                                           Drives and controls, motors and mechanical power transmission catalogue  71