                                                      Driver 2.42 mm
                                             Driver 2.42; with hex/square Ratchet connection   7 mm  CT-S207
                                             Driver 2.42; with hex/square Ratchet connection  10 mm  CT-S210

                                             Driver 2.42; with hex/square Ratchet connection  15 mm  CT-S215

                                             Driver 2.42; with hex/square Ratchet connection  18 mm  CT-S218
              Length
                                             Motor Mount 2.42 Hex.                      20 mm    CT-0252
                                             Motor Mount 2.42 Hex.                      28 mm    CT-0254

                * For installation of implants at the implant level or at the abutment level in premium packages
                  where the driver interface with the internal hex of the connector abutment CO-8036.
                * The implant insertion with the motor-mount driver should be 30 rpm or less.
                * Notice: the hexagon position of the driver reflects the position of the internal hexagon of the implant.
                * During the insertion try to put the flat part of the hex parallel to the buccal of the bone ridge.



                                                         Drivers

                                   Screw Driver   Hex Implant              Conical Implant Drivers
                                                   Driver











                                    1.25 mm       2.42 mm        Narrow         Regular        Wide
                     Length       Cat Number
                     10 mm          CT-D110       CT-H210        MCT-N210      MCT-R210       MCT-W210
                     15 mm          CT-D115       CT-H215        MCT-N215      MCT-R215       MCT-W215
                     20 mm          CT-D120       CT-H220        MCT-N220      MCT-R220       MCT-W220
                1.25mm:
                *  For installation or removal of cover screws, healing caps. abutment screws and multi-unit system components.
                *  The motor-mount is used with a latch type contra-angle hand piece.
                *  The implant insertion with the motor-mount driver should be 30 rpm or less.
                *  Notice: the hexagon position of the driver reflects the position of the internal hexagon of the implant.
                *  During the insertion try to put the flat part of the hex parallel to the buccal of the bone ridge.