Field mountable paperless recorder 7 Configuration
7.10 I/O Module Configuration
Fig. 7.17 I/O Module Configuration
Note. The recorder detects the type of module fitted in each position automatically.
7.10.1 Analog Inputs
Set the mains rejection frequency used to filter electrical noise induced on the signal lines by power supply cables.
Set to 'On' to enable input adjustment from Logging menu – see page 50.
Note. The following parameter is displayed only if recording is enabled during configuration, i.e. the 'Disable recording in configuration' check box is not ticked on entry to the Configuration level – see Fig. 7.1, page 66.
Input Adjustment
Manually fine-tune inputs to remove process offset errors or system scale
errors.
Note.
Changes to the Analog Input Type (see page 96) must be saved to the current configuration before commencing input adjustment.
For dual input modules, 2 channels can be adjusted.