tile batten ☐ 20x30mm
                                                                                                     end common rafter ☐ 50x100mm
                                                                                                          hip rafter ☐ 50x100mm
                                                                                                          jack rafter ☐ 50x100mm
                              thatch roof, t=150mm                                                        top plate ☐ 50x100mm










                                                                                                        main column ☐ 100x100mm


            timber floor 150, t=20mm                                                                     sub clumn ☐ 50x100mm
            handrail ☐ 30x60mm
            baluster ☐ 30x60mm
            stread ☐ 30x250mm                                                                                                   handrail ☐ 30x50mm
            stringer ☐ 40x200mm                                                                                                 stringer ☐ 40x200mm
                                                                                                                                 stread ☐ 30x250mm
                                                                                                                           terrace sub column  ☐ 50x80mm
                                                                                                                              timber floor 150, t=20mm
                                                                                                                                handrail ☐ 30x50mm
                                                                                                                                baluster ☐ 50x50mm
                                                                                                                               newel post ☐ 30x30mm
                                                                                                                               bottom rail ☐ 30x50mm















                                                                                                                                    terace beam  ☐ 60x120mm
           connector point of main column                                                                                          terrace sub beam ☐ 40x80mm
           trust ☐ 50x120mm                                                                                                          terrace strut ☐ 60x120mm
           sub beam ☐ 40x60mm
           beam ☐ 60x120mm                                                                                                         terrace column ☐ 60x120mm
           center column ☐ 100x100mm                                                                                           stainless steel plate joint to the rock
           girt stick ☐ 50x100mm
           foundation by reinforced concrete
                                                                                                                                             ground