4.3 Ground Conditions Encountered
The ground conditions encountered in the low lying area at the base of the slope (the proposed building location) and on the slope are summarised in Tables 2 & 3 respectively:
Table 2: Ground Conditions in Low Lying Area
5
      Stratum
 Description
    Depth to top of stratum from existing ground level
m
       Thickness of Stratum
m
   Typical CPT Tip Resistance
MPa
      1
 Dark brown sandy SILT (Topsoil/Fill)
    -
       0.7 to 1.2m
   1 to 2
     2
    Brown & grey stiff sandy SILT (Alluvial)
    0.7 to 1.2
       0.2 to 0.5
      2
    3
Very loose to medium dense SAND (Alluvial)
 0.8 to 1.2
  1 to 3
 1 to 12
     4
    Stiff to very stiff SILT (Hamilton Ash/Matua Subgroup Silt)
    2 to 4
       7 to 8
      2 to 4
    5
   Medium dense to dense SAND (Matua Subgroup Sand)
  10 to 11
    -
    8 to 12
  The groundwater level was measured at 0.6 to 1m depth.
Table 3: Ground Conditions on Slope
      Stratum
 Description
    Depth to top of stratum from existing ground level
m
       Thickness of Stratum
m
   Typical Shear Vane Reading
kPa
      6
    Stiff sandy SILT & Loose silty SAND with up to 700mm of topsoil (Younger Ash)
     -
         1.5 to 1.7
      90
    4
   Dark brown and white and brown mottled, very stiff plastic SILT (Hamilton Ash/Matua Subgroup Silt)
  1.5 to 1.7
    3.5 +
    120
  The ground water level was not identified in the slope investigation.
6c Myrtle Drive, Omokoroa Project 533
O’Brien Geotech Ltd February 2017