Page 29 - Apave Oil and Gas 2016
P. 29

NDT - CUI Inspection






            Long Range Ultrasonic Testing – LRUT






              •    Detection of corrosion or erosion under insulation
              •    Oil and gas pipeline
              •    Offshore pipelines
              •    Raised or complex pipelines with restricted access
              •    Buried pipelines that run under buildings, roads
              •    Temperatures from -40 to 120°C

              •    Maximum distance for inspection is from 15-150m


































                                                        Apave Oil and Gas Presentation - 2016