Page 120 - Microsoft Word - 2_Inch_Drain_Adapter_PDS_2016_01_05
P. 120

®
                                           ®
                             DURO-GUARD  SECUROCK  GYPSUM-FIBER 3/8-INCH ROOF BOARD

            Installation:                                             o Duro-Grip CR-20.
                 In steel deck applications, Securock Gypsum-        Subsequent layers of insulation and approved
                 Fiber Roof Board can only be used as a cover         cover boards may be attached with insulation
                 board over insulation or as recover board over       adhesive.
                 an existing roof. It may be placed directly on
                 flute filler in a metal roof retrofit application   Hot Bitumen Attachment
                 assuming the flutes are completely filled.           When using hot bitumen on concrete decks,
                                                                      priming is necessary.
                 Panels must be kept dry before, during and
                 after installation. Install only as much insulation      Temperature of the bitumen shall be
                 as can be covered the same day with                  approximately 50° F below the inter-ply hand
                 completed roofing.                                   mopping EVT.
                 The use of multiple layers of insulation with       The deck shall be dry and care must be taken
                 joints staggered a minimum of 6 inches               to apply the bitumen in sufficient quantity to
                 between layers is recommended to eliminate           totally cover the available deck surface.
                 thermal bridging.
                                                                      To ensure embedment, the board shall also be
                 Abut panel edges loosely (minimum of 1/16-          “stepped in” at several points while the bitumen
                 inch gap on all sides) and stagger joints of         is still hot enough to allow positive attachment.
                 adjacent panels. Gaps may need to be larger
                 depending on factors like the roof deck's size,      Any roof membrane contaminated with bitumen
                 membrane color, deck surface temperature and         must be replaced.
                 time of year the roof assembly is installed.
                                                                 Storage:
                 Gaps must be no greater than 1/4 inch around
                 all penetrations.                                    Must be protected from open flame and kept
                                                                      dry at all times.
                 Refer to the appropriate Duro-Last roof system
                 specification and detail drawings for deck           Factory applied packaging is intended only for
                 preparation and attachment requirements.             protection during transit. Slit or remove the
                                                                      packaging to prevent accumulation of
                 Precautions must be taken to ensure that new        condensation.
                 concrete decks have fully hydrated and do not
                 continue to release moisture.                        Store elevated (at least 3 inches) and
                                                                      completely covered with a weatherproof
            Panel Attachment:                                         covering such as a tarpaulin.
                 Panels may be attached to the roof deck using       Do not use panels which are wet or damaged.
                 mechanical fasteners, insulation adhesive or         Refer to PIMA Technical Bulletin No. 109:
                 hot bitumen. It is acceptable to use these           Storage and Handling Recommendations for
                 products in combination.                             Polyiso Roof Insulation for additional guidelines

             Mechanical Attachment                                    (www.pima.org).
                 When installing multiple layers (which may     Limitations:
                 include insulation, cover boards and thermal         Duro-Last, Inc. will not be responsible or liable
                 barriers) it is acceptable to mechanically secure    for any defects or problems related to building
                 through all layers.                                  or roof design by others, to deficiencies in
                 Use fasteners and plates supplied by or             construction, to dangerous conditions on the
                 approved by Duro-Last, Inc.                          job site, or to improper storage, handling or
                                                                      installation by others.
             Adhesive Attachment
                 Insulation adhesive must be supplied by Duro-
                 Last, Inc. Refer to the adhesive’s Product Data
                 Sheet for application guidelines. Acceptable
                 products:
                            ®
                 o Duro-Grip  Insta-Stik™.
                                       ®
                 o Duro-Grip Olybond500 .
                                                 ®
                 o Duro-Grip Millenium Weather-Tite .
               www.duro-last.com                            2 of 2                             800-248-0280
           Duro-Last, Duro-Guard, Duro-Grip, Duro-Bond and “World’s Best Roof” are registered marks owned by Duro-Last, Inc. Weather-Tite is a registered mark owned by Millenium Adhesive Company.
                  Securock is a registered mark owned by USG Corporation. RoofNav is a registered mark owned by FM Global. Olybond500 is a registered mark owned by OMG, Inc.
                                                   Created: 01/12/2015 Revised: 05/07/2015