                                        5/8-INCH ROOF BOARD


            Description                                          Moisture Management
                     ®
            DensDeck  Prime Roof Board has been enhanced to      DensDeck Prime Roof Boards, like other
            provide a broader compatibility and higher           components used in roofing systems, must be
            performance with roofing adhesives. Face mat         protected from exposure to moisture before,
            enhancements allow adhesives to be applied more      during and after installation.
            uniformly and consistently. DensDeck Prime Roof
            Boards reduce the amount of mastic or adhesive       Remove the plastic packaging from all DensDeck
            used and potentially eliminates field primers. The   Prime Roof Board immediately upon receipt of
            DensDeck Prime Roof Board design employs             delivery. Failure to remove the plastic packaging may
            fiberglass mats front and back that are mechanically   result in entrapment of condensation or moisture.
            bonded to a high density gypsum core, providing      DensDeck Prime Roof Board stored outside must be
            excellent fire resistance and wind uplift properties.   stored level and off the ground and protected by a
            The unique construction of DensDeck Prime Roof       breathable waterproof covering. Provide means for air
            Board provides superior flute spanning that stiffens   circulation around and under stored bundles of
            and provides increased foot traffic resistance to the   DensDeck Prime Roof Board. DensDeck Prime Roof
            roof deck. Additionally, DensDeck Prime Roof Board   Board must be covered the same day as installed.
            has been shown to withstand delamination,
            deterioration and job-site damage far more effectively   Avoid application of DensDeck Prime Roof Boards
            than roofing membrane substrates such as             during rain, heavy fog and any other conditions that
            paperfaced gypsum board, fiberboard and perlite      may deposit moisture on the surface, and avoid the
            insulation.                                          overuse of non-vented, direct-fired heaters during
                                                                 winter months. When roofing systems are installed on
            Primary Uses                                         newly poured concrete or light weight concrete decks
            DensDeck Prime Roof Board can be used as a           or when re-roofing over an existing concrete deck, a
            recovery board and overlayment protection board for   vapor barrier should be installed above the concrete
            polyisocyanurate and polystyrene insulation.         to limit the migration of water from the concrete into
                                                                 the roof assembly. Always consult a design authority
            Standards and Code Approvals                         for specific instructions for applying other products to
            DensDeck Prime Roof Boards are manufactured to       DensDeck Prime Roof Boards.
            meet ASTM C1177 and have the following approvals:
            • Florida Product Approved                           Moisture vapor movement by convection must be
            • Miami-Dade County, Product Control Approved        eliminated, and the flow of water by gravity through
                                                                 imperfections in the roof system must be controlled.
            Recommendations and Limitations                      After a leak has occurred, no condensation on the
            DensDeck Prime Roof Boards are manufactured to       upper surface of the system should be tolerated, and
            act with a properly designed roof system following   the water introduced by the leak must be dissipated
            good roofing practices. The actual use of DensDeck   to the building interior in a minimum amount of time.
            Prime Roof Board as a roofing component in any
            system or assembly is the responsibility of the roofing   Although DensDeck Prime Roof Boards are
            system’s design authority. Consult with the          engineered with fiberglass facings and high density
            appropriate design authority for system and assembly   gypsum cores, the presence of free moisture can
            specifications and instructions on applying other    have a detrimental effect on the performance of the
            products to DensDeck Prime Roof Board.               product. Moisture accumulation may also significantly
                                                                 decrease wind uplift and vertical pull resistance in the
            DensDeck Prime Roof Boards should not be             system or assembly. DensDeck Prime Roof Boards
            subjected to abnormal or excessive loads or foot     containing excessive free moisture content may need
            traffic, such as, but not limited to, use on plaza decks   to be evaluated for structural stability to assure wind
            or under steel-wheeled equipment that may fracture   uplift performance.
            or damage the panels. Provide suitable roofing
            system protection when required.





               www.duro-last.com                            1 of 2                             800-248-0280
                                    Duro-Last, Duro-Guard and “World’s Best Roof” are registered marks owned by Duro-Last, Inc.
                            DensDeck is a registered mark owned by Georgia-Pacific Gypsum LLC. RoofNav is a registered mark owned by FM Global.
                                                        Created: 01/07/2015
   44   45   46   47   48   49   50   51   52   53   54