BIOSAFETY
Nadiso - NDS Series
BSL : Build upon BSL-1, BSL Nadiso integrated Lab bench Design BSL
ergonomic, Standar Room BSL, NBCS, and Smart Lab. BSL Level 2
Nadiso Series made to meet standard microbiological practice Nadiso Series :
The laboratory supervisor must enforce the Room :
institutional policies that govern control to the
laboratory using SMART LAB NDS - 01. - Laboratory door with self-closing system
accompany with institutional polices that govern
Personnel must wash their hands before and after and control person that allowed to access lab;
working with hazardous materials and before leaving - Air Lock Shower for Person - NDS Airlock;
in laboratory; Sink & Safety Shower for safety. - Pass Box For Object or material - Passbox NDS;
- Floor using Coating min 2000 micron with curve;
- Wall room using panel, polycarbonate sheet
rockwool or sandwich panel to avoid virus or
Eating, drinking, smoking, handling contact lens, bacteria growth up.
applying cosmetic, and storing food for user
consumption must not be permitted, stored outside Laboratory Furniture :
lab using cupboard or racking. - High-chemical resistance Top Table using Phenolic
Resin that resist to water, heat, organic, solvent,
Mouth pipetting is prohibited, mechanical pipetting acid, and others chemical substance;
devices must be used - Chair used NDS Lab Stool, covered with PP, with
a non-porous material;
- BSC Using NBCS, Integrated with Scrubber IPAL;
BSL level 2 Nadiso completed with labelling room for - Fume Hood using NDS FH 1300 or 1500 metal base
safety and policies placed in each corner of room, Top with Phenolic Resin Fundermax 16 mm;
a sign incorporating the universal biohazard symbol - Laminar air flow NDS.
must be posted
HEPA FILTERED AND SYSTEM AIR HANDLING UNIT
Hepa filter exhaust air from class II BSC can be Deviced used to regulate and circulate air as part of a heating,
safely re-circulated back into the laboratory ventilating, and air-conditioning (HVAC) system.[1] An air handler is
environment if the cabinet is tested and certified usually a large metal box containing a blower, heating or cooling
at least annually and operated according to elements, filter racks or chambers, sound attenuators and dampers.
manufacturer's recommendation, Nadiso BSC
class II ( NBCS) also connected to the laboratory Air handlers usually connect to a ductwork ventilation system that
exhaust system connect with Scrubber IPAL to distributes the conditioned air through the building and returns it to the
give extra layer of safety level AHU. Sometimes AHUs discharge (supply) and admit (return) air directly
Cabinet performance and air system operation. to and from the space served without ductwork. NADISO AHU refer AHU
with Class ISO 3 , 10.000 particle.