Page 30 - ALLOY Partitioning Systems
P. 30

(Sound Transmission Class)



            Introduction.




            ALLOY
            tested for sound transmission performance.

            Test Method                                        Measurement Results
            Specimen were installed between two reverberation   The Transmission Loss is determined by the sound
            chambers The space and time averaged sound         levels on both sides of the sample and analyzing
            pressure levels in the two rooms were determined,   the data in accordance with ISO 10534-2 (1998).
            as well as the sound absorption in the receiving   The airborne sound transmission loss  (TL) of the
            room. The sound pressure levels in the two rooms,   test sample for each individual 1/3 octave band
            the sound absorption in the receiving room and     center frequency and the STC rating number is
            the area of the specimen was used to calculate the   shown in the next page.
            transmission loss value.
                                                               The graphical representation of the values in
            The air temperature and the relative air humidity    the table is also shown.
            in both the source and receiving room were
            measured. BS EN ISO 717-1:1997, “Acoustics         The calculated weight noise reduction as
            – Rating of sound insulation in buildings and of   described in ISO 717-1 is 45 dB.
            building elements” was used in the interpretation
            and calculation of the results.






            DSG The sound transmission-loss measurements of the double glazing panel












            Stimulus                                                Response




            30   ALLOY
   25   26   27   28   29   30   31   32   33   34   35