  120
6. CONDITIONING OF SALINE WATER
 FIGURE 6.4
Coagulant accumulation on cartridge filters due to iron coagulant overdosing.
Coagulant residue on the reverse osmosis membrane feed due to iron coagulant overdosing.
 FIGURE 6.5
6.2.3 Design Example
6.2.3.1 In-line Static Mixer
Eq. (6.1) is applied for seawater desalination plant with a fresh water production capacity of 50,000 m3/day [13.2 million gallons per day (MGD)] and intake flow of 127,910 m3/day (33.8 MGD 1⁄4 28,190 gpm), a 30-in. diameter mixer with a length of 5.0 ft, and Dp of 0.5 psi, and the G  T 1⁄4 (1212  30-in.)/[(0.5 psi  5 ft  12 in.)/23,472 gpm]0.5 1⁄4 1300. The opti- mum G  T mixing range is usually between 500 and 1600.