EOS 90398-A_PHY-0004-Frames and transformer assembly
5. Install Hydraulic power pack – The ladder frame could be installed first but sometimes it easier to
do the hydraulic unit first as you will have more space around it. It is a matter of preference.
a. Mount the hydraulic pump assembly
behind the Frontal column
b. The hydraulic pump mounts directly to
the back of the frontal column
approximately 21cm from the base.
(minimum = 17cm) so it does not
interfere with the metal frame position.
c. You need two people to safely mount
the hydraulic pump assembly