Page 357 - METRO CENTER PDF BINDER 1_Neat
P. 357

Marlite Guide Specification                                                                                                      09/02/2016
               Decorative FRP Wall Panels

                              b.    Space at in field in rows 16’ (40.64cm) on center, with fasteners spaced at 12”
                                    (30.48 cm) maximum on center.

                  C.    Apply panels to board substrate, above base, vertically oriented with seams plumb and pattern
                        aligned with adjoining panels.
                        1.    Install panels with manufacturer's recommended gap for panel field and corner joints.
                              a.    Adhesive trowel and application method to conform to adhesive manufacturer’s
                                    recommendations.
                              b.    Drive fasteners for snug fit.  Do not over-tighten.
                  D.    Apply panel moldings to all panel edges using silicone sealant providing for required
                        clearances.
                        1.    All moldings must provide for a minimum 1/8 “ (3mm) of panel expansion at joints and
                              edges, to insure proper installation.
                        2.    Apply sealant to all moldings, channels and joints between the system and different
                              materials to assure watertight installation.


               3.3      CLEANING

                  A.    Remove excess sealant from panels and moldings.  Wipe panel down using a damp cloth and
                        mild soap solution or cleaner.

                  B.    Refer to manufacturer's specific cleaning recommendations Do not use abrasive cleaners.



               END OF SECTION 09 7720









































                Decorative Fiberglass Reinforced Wall Panels                                09 7720  - 9