Page 243 - TORO PRODUCT CATALOGUE NOV_2019
P. 243

    R Century Plus Scrubber Valves cont.
        Added Features
• Flow control allows flow adjustment and manual shutoff
• EPDM valve seat seal
• Encapsulated injection-moulded solenoid with a captive hex plunger 24 VAC
• Positive O-ring seal on inlet plug prevents leaks without damaging seal threads
• Moulded-in and anchored studs allow positive bonnet attachment and removal
• Brass flow control stem on 50 and 80 mm models
• Easily serviced without removal from the system
• Five-year warranty
Operating Specifications
• Flow range: 20-1100 Lpm
• Pressure range: 140-1500 kPa
Electrical Specifications
• Solenoid: 24 VAC
• Inrush volt-amp: 24 VAC - 9.6 VA • Inrush current: 0.4 amp
• Holding volt-amp: 24 VAC - 4.8 VA • Holding current: 0.2 amp
Options Available
 • OmniReg® 35-210 kPa regulator (OMR-30)
• OmniReg® 35-700 kPa regulator (OMR-100)
• DC latching solenoid (DCLS-P) Note: Maximum pressure for a valve that utilizes latching solenoid is 820 kPa.
* Optional accessories are field-installable. Must specify separately if required.
    Ordering Information
 Code
   Description
   100P1-BSP-S
 Century Plus 25 mm FBSP Solenoid Valve with Flow Control and Continuous Self Cleaning Filter
 100P1.5-BSP-S
   Century Plus 40 mm FBSP Solenoid Valve with Flow Control and Continuous Self Cleaning Filter
   100P2-BSP-S
 Century Plus 50 mm FBSP Solenoid Valve with Flow Control and Continuous Self Cleaning Filter
 100P3-BSP-S
  Century Plus 80 mm FBSP Solenoid Valve with Flow Control and Continuous Self Cleaning Filter
         Dimensions (D × W × H)
  D (mm)
   W (mm)
   H (mm)
  100P1-S
   121
  92
  172
  100P1.5-S
  121
 92
 185
 100P2-S
 197
  156
  242
 100P3-S
 210
  156
  273
      Century Plus Scrubber Valve Friction Loss Data – kPa
 Size
 Configuration
     Flow Rate Lpm
 20
  40
  60
  80
  100
  120
  140
  160
  180
  200
  250
  300
  350
  400
  450
  500
  550
  600
  700
  800
  900
  1000
  1100
  25 mm
 Globe Angle
  31 30
33 33
  24 24
18 17
  28 27
40 40
  53 54
 69 69
88 85
                40 mm
 Globe Angle
    7 7
 8 8
 10 10
 15 14
 20 18
 25 22
 31 27
 48 41
 69 61
 95 81
 125 105
          50 mm
 Globe Angle
            22 19
 32 28
 42 35
 54 42
 66 54
 80 66
 92 78
      80 mm
 Globe Angle
                           23 18
 31 25
  40 34
 49 43
  60 54
 73 65
  Shading indicates flow range.
Flow rates are recommended not to exceed 35 kPa loss.
  227
 
   241   242   243   244   245