Page 243 - TORO PRODUCT CATALOGUE NOV_2019
P. 243
R Century Plus Scrubber Valves cont.
Added Features
• Flow control allows flow adjustment and manual shutoff
• EPDM valve seat seal
• Encapsulated injection-moulded solenoid with a captive hex plunger 24 VAC
• Positive O-ring seal on inlet plug prevents leaks without damaging seal threads
• Moulded-in and anchored studs allow positive bonnet attachment and removal
• Brass flow control stem on 50 and 80 mm models
• Easily serviced without removal from the system
• Five-year warranty
Operating Specifications
• Flow range: 20-1100 Lpm
• Pressure range: 140-1500 kPa
Electrical Specifications
• Solenoid: 24 VAC
• Inrush volt-amp: 24 VAC - 9.6 VA • Inrush current: 0.4 amp
• Holding volt-amp: 24 VAC - 4.8 VA • Holding current: 0.2 amp
Options Available
• OmniReg® 35-210 kPa regulator (OMR-30)
• OmniReg® 35-700 kPa regulator (OMR-100)
• DC latching solenoid (DCLS-P) Note: Maximum pressure for a valve that utilizes latching solenoid is 820 kPa.
* Optional accessories are field-installable. Must specify separately if required.
Ordering Information
Code
Description
100P1-BSP-S
Century Plus 25 mm FBSP Solenoid Valve with Flow Control and Continuous Self Cleaning Filter
100P1.5-BSP-S
Century Plus 40 mm FBSP Solenoid Valve with Flow Control and Continuous Self Cleaning Filter
100P2-BSP-S
Century Plus 50 mm FBSP Solenoid Valve with Flow Control and Continuous Self Cleaning Filter
100P3-BSP-S
Century Plus 80 mm FBSP Solenoid Valve with Flow Control and Continuous Self Cleaning Filter
Dimensions (D × W × H)
D (mm)
W (mm)
H (mm)
100P1-S
121
92
172
100P1.5-S
121
92
185
100P2-S
197
156
242
100P3-S
210
156
273
Century Plus Scrubber Valve Friction Loss Data – kPa
Size
Configuration
Flow Rate Lpm
20
40
60
80
100
120
140
160
180
200
250
300
350
400
450
500
550
600
700
800
900
1000
1100
25 mm
Globe Angle
31 30
33 33
24 24
18 17
28 27
40 40
53 54
69 69
88 85
40 mm
Globe Angle
7 7
8 8
10 10
15 14
20 18
25 22
31 27
48 41
69 61
95 81
125 105
50 mm
Globe Angle
22 19
32 28
42 35
54 42
66 54
80 66
92 78
80 mm
Globe Angle
23 18
31 25
40 34
49 43
60 54
73 65
Shading indicates flow range.
Flow rates are recommended not to exceed 35 kPa loss.
227