Page 37 - Quell-user_manual_update_321
P. 37

< Contents  |  APPENDIX I: Electromagnetic Compatibility Declaration




            APPENDIX I
            Electromagnetic Compatibility Declaration




            Quell is intended for use in the electromagnetic environment specified below. The user
            should ensure that it is used in such an environment.


             Emissions test          Compliance                 Electromagnetic environment – guidance
             RF emissions; CISPR 11  Group 1                    Quell uses RF energy only for its internal  function. Its
                                                                RF emissions are very low and are not likely to cause
                                                                any interference in nearby  electronic equipment.
             RF emissions; CISPR 11  Class B                    Quell is suitable for use in all establishments,
                                                                including domestic establishments and those  directly
                                                                connected to the public low voltage power supply
                                                                network that supplies buildings used for domestic
                                                                purposes.
             Harmonics Current       Class A
             Emissions IEC 61000-3-2
             Fluctuations and Flicker   Complies
             IEC 61000-3-3
             Electrostatic Discharge   +/- 15kV air; +/- 8kV contact  Floors should be wood, concrete or ceramic tile.
             Immunity (ESD);                                    If floors are covered with synthetic material, the
             IEC 61000-4-2                                      humidity should be at least 30%
             Radiated RF;            10 V/m; 80 MHz to 2.7 GHz  10 V/m compliance level
             IEC 61000-4-3
             Electric Fast Transient   ±2kV power leads         Mains power quality should be that of a typical
             Burst Immunity                                     domestic establishment.
             IEC 61000-4-4
             Fast Surge Immunity     ±2kV Common mode
             IEC 61000-4-5
             Radio Frequency         3 VRMS (80% AM at 1 kHz);
             Common Mode Immunity  150 kHz to 80 MHz
             IEC 61000-4-6
             Power Frequency         30 A/m 50 Hz
             Magnetic Field Immunity
             IEC 61000-4-8
             Voltage Dip and Interrupt  Complies                Mains power quality should be that of a typical
             Immunity IEC 61000-4-11                            domestic establishment.















            Quell  User Manual    Quell Customer Care 1-800-204-6577 or +1-781-890-9989
                ®
                                                                                                               36