Page 165 - Eurotec-Ltd-Price-Book-2017-2018-Online
P. 165

Terms and Conditions apply. Subject to change without notice  Prices are GST Exclusive Items per unit unless otherwise stated
                                       Audio/Visual Indication To EN 981

                           Visual                                               Audio
              Colour                Meaning                 Characteristics           Configuration of time
                                                          -With variable frequency
                                     DANGER                                         - ON/OFF, continuous or alternating
             RED                 Urgent intervention to      -Series of sounds           - ON/OFF, alternating
                                   save or protect       -Alternate tone (two or three   - ON/OFF, continuous or alternating
                                                            frequency intervals
        Yellow / Orange                                                            -Alternating ON/OFF, which must be
                                                                                   clearly different from “”EMERGENCY
                                    ATTENTION           One sound only with a constant     EVACUATION”
           Orange             Intervention when necessary  spectrum, minimum duration: 0.3s  “Max 2 different “”ON”” segment lengths
                                                                                 can be in” the configuration; the first one is
                                                                                             to be long
                                    COMMAND
             Blue            Compulsory intervention required  -Two or three different sounds,   -ON/OFF, continuous or alternating
                                                         each of them with a constant
                                                               spectrum
           White /               ANNOUNCEMENT /         -Ringing tone consisting of two   -Non-repetitive high-low (followed by
                                   INFORMATION
             Clear              Instruction to the public        tones                      instructions)
                                                                                       -Continuous, at least 30s
                                   END OF ALARM
            Green                                      -Sound with consistent spectrum  - Signal which follows one previous alarm
                                Situation: Out of danger
                                                                                              signal
                              Process Condition Indicator Colours To EN 60073
              Colour          Meaning         Explanation        Operator Actions           Application
                                                                                      -Pressure/temperature out of safe
                                                                Immediate action to deal        limits
                                                               with a dangerous condition
                                                                       by, eg;               -Voltage drop
              RED             Emergency     Dangerous conditions  - Activate emergncy stop  -Breakdown of a ”main”” unit”
                                                                                    -Breakdown of critical control systems
                                                                 - Opening safety valve
                                                                                       -Freezer temperature too high
                                                                  - Start cooling pump
                                                                                     -Stop position over travel on a hoist
        Yellow / Orange                                                              -Pressure/temperature different from
                                                                                             normal levels
                                                                                      -Tripping of a protective device or
                                                                                             auxiliary unit
                               Unusual       Abnormal conditions  Monitoring and/or inter-  -Conveyor overload
                                                                 vention (reset intended
           Orange              Conditions  Impending critical condition  function)      -Over travel of a limit  switch
                                                                                    -Position change of a valve or convey-
                                                                                                or belt
                                                                                         -Freezer on ”super” freeze

            Green               Normal       Normal conditions        Optional           -Authorisation to proceed
                                                                                      -Indication of normal working limits

              Blue             Mandatory   Indication of a condition   Mandatory actiuon  Instruction to operator to enter
                                             that requires action
                                                                                           preselected values
            White /           No specific   Any meaning; may be used                      Instruction to operator
                                            whenever doubt exists
             Clear            meaning as-  Red, Yellow, Green, Blue  Mandatory actiuon     to enter preselected
                                           about the application of
                                signed


       164            AUCKLAND 09-579 1990     WELLINGTON 04-499 3591    CHRISTCHURCH 03-366 0017
                    HVAC - Refrigeration - Electrical - Measurement    www.eurotec.co.nz