Page 351 - B6118-AEW-XX-XX-PP-A-0001_(P19)_Contractors Manual
P. 351
CONSTRUCT
C3 Shopfitting
C3.1 Stud Walls
New studwork walls to be constructed from Wall bottom track to be set 20mm off the floor
Gyproc MF proprietary system to suit the level, seated on a 20mm concrete particle
scenario. Stud sizing, centres, fixing details and board sole plate. Wall boards to be set 15mm
all other details should be as manufacturers off the floor level to avoid capillary action prior
recommendations contained in The White Book: to any finishes being installed.
http://www.british-gypsum.com/~/media/ Stud wall boards facing into new presenter
Files/British-Gypsum/WHITE-BOOK/WHITE-BOOK- booths should be balance laminate with sealed
Partition-Wall-Systems-Section.pdf PVC edges (to prevent capillary action) ready
for final graphic decoration.
All walls to be suitably retained at the head
back to soffit.
C3.1 Stud Walls 2.0 09 February 2017