CONSTRUCT
C3 Shopfitting
C3.17 Self Order Kiosks Wall Mounted
The location and type of self order kiosks will Wall mounted units to be mechanically fixed to
be identified on the architect’s site specific the wall using all available location holes in the
drawings and ordered by McDonald’s for the unit fixing plate. Weights of wall mounted SOK’s
principal contractor to call off. Regardless of may vary dependant on manufacturer; but
supplier there are two general types: are generally 100kg each; principal contractor
to check supplied weight and ensure that the
Freestanding mounting wall is suitably constructed to fix to,
including:
Freestanding units to be mechanically fixed to
the floor using all available location holes in the - Stud size and centres
unit base plate. Above the ceiling, restraint must
be installed to the head of the units utlising the - Restraint to soffit
same detail as furniture screen fixing.
- Wall linings
Small power (1x) and data (4x) must be provided
to this location (left coiled up below the ceiling) Upgrade works to be undertaken as appropriate.
by the principal contractor to coincide with its
fixing post. Small power (2x) and data (2x) must be provided
to this location by the principal contractor within
Floor mounted kiosks are generally 140kg each. the wall void.
Installation to be in line with the following:
- Acrelec NGK Installation Guide N-E-B
01-A-12008-001 REV 1.0
- Acrelec NGK Installation Guide N-E-B
01-A-12008-001 REV 2.0
- Acrelec Wall NGK Installation Guide N-E-F
01-A-12008-002 REV 1.0
- Acrelec Kit Installtion Guide K113017005-1 Rev
1.0
- Acrelec NGK32” Pre Installtion V1.0 (14.03.14)
- Kiosk Floor Fed Dependencies
C3.17 Self Order Kiosks 3.0 25 July 2017