Page 448 - B6118-AEW-XX-XX-PP-A-0001_(P15)_Contractors Manual_Neat
P. 448
CONSTRUCT
C3 Shopfitting
C3.11 Counter Gates C3.12 Internal Doors
Counter access gate usually form part of the fire Any replacement doors must be solid core, with
exit strategy for crew members working in the hardwood lippings and finished in balanced
kitchen. As such their size is critical. A clear space laminate as identified on the architect’s site
of 900mm must be left between fixed finishes for specific drawings.
the counter gate to operate in allowing 50mm
for the post and a clear 850 when the gate is in Where existing door frames are mild steel type or
the open position. The gate must open into the have been identified by the project manager as
dining area. requiring replacement then full door and frame
sets can be ordered using the same process.
Following the installation of new wall finishes,
both laminate panels and/or ceramic tiles, if
insufficient cover is provided by the existing door
frame reveal, then an additional rectangular
HW capping must be installed to provided min
5mm positive cover in front of the line of new
finishes. The new HW architrave must be finished
to match the door frames which are generally
lacquered oak or painted. New architraves
must be installed to each side and door head
with 45 degree mitred corners.
C3.11 Counter Gates 1.0 08 October 2014
C3.12 Internal Doors 1.0 08 October 2014