CONSTRUCT





       C3 Shopfitting






       C3.11 Counter Gates                                    C3.12 Internal Doors

       Counter access gate usually form part of the fire      Any replacement doors must be solid core, with
       exit strategy for crew members working in the          hardwood  lippings  and  finished  in  balanced
       kitchen. As such their size is critical. A clear space   laminate  as  identified  on  the  architect’s  site
       of 900mm must be left between fixed finishes for       specific drawings.
       the counter gate to operate in allowing 50mm
       for the post and a clear 850 when the gate is in       Where existing door frames are mild steel type or
       the open position. The gate must open into the         have been identified by the project manager as
       dining area.                                           requiring replacement then full door and frame
                                                              sets can be ordered using the same process.


                                                              Following  the  installation  of  new  wall  finishes,
                                                              both laminate panels  and/or ceramic tiles, if
                                                              insufficient cover is provided by the existing door
                                                              frame  reveal, then  an  additional rectangular
                                                              HW capping must be installed to provided min
                                                              5mm positive cover in front of the line of new
                                                              finishes. The new HW architrave must be finished
                                                              to match the door frames which are generally
                                                              lacquered oak or painted. New architraves
                                                              must be installed to each side and door head
                                                              with 45 degree mitred corners.