Page 154 - LNA Standards Manual 2018 update
P. 154

Acoustics BLOCK      Transmission Class (STC) rating of any assembly should be 40 or better.
                                   any assembly should be 46 or better.  Back-to-back outlets should not
                                In conference rooms, training rooms and executive offices the STC of

                          Where fixed, ceiling-high, drywall partitions are used, the Sound





















                                        hardening acoustic sealant.  be used and all walls should be sealed to structure with non-    Ceiling-high mullion-less glass partitions must have joints caulked.      Doors should be solid core wood or acoustic lined and should have  an automatic door bottom and a fully gasketed interface between  the door and frame.  Glass doors should be laminated and fully   framed.     Flanking paths should be limited in the overall design of the space.