Page 202 - TeeJet Catalog
P. 202
PLUMBING DIAGRAMS
To Sprayer Control
A
LineB I
Agitation Line
H
E
C
Bypass
D
D
Centrifugal Pump
F To Sprayer Control
C
G
TWO-WAY PLUMBING DIAGRAM
(Non-Positive Displacement)
A – Tank Rinsing Nozzle B – Eductor Nozzle
C – Manual Shutoff Valve D – Throttling Valve
E – Line Strainer
F – Electric Regulating Valve
G – Flowmeter
H – 2-Way Boom Control Manifold
I – Nozzle Bodies & Spray Tips
To Sprayer Control
A
LineB I
D Agitation Line
E
C
D
Bypass
H
Centrifugal Pump
F
To Sprayer Control
C
G
FLOW BACK PLUMBING DIAGRAM
(Non-Positive Displacement)
A – Tank Rinsing Nozzle B – Eductor Nozzle
C – Manual Shutoff Valve D – Throttling Valve
E – Line Strainer
F – Electric Regulating Valve
G – Flowmeter
H – Flow Back Boom Control Manifold
I – Nozzle Bodies & Spray Tips
NON-POSITIVE DISPLACEMENT PUMP
The centrifugal pump is the most common non-positive displacement pump. The output from this type of pump is influenced by pressure. This pump is ideal for delivering large volumes of liquid
at low pressures. A key component of the centrifugal pump is the throttling valve. A manual throttling valve on the main output line is essential for the accurate operation of the centrifugal pump.
202 TEEJET® TECHNOLOGIES
Distributed By: Sensor-1 • 202 Main Street, Princeton, KS 66078 • 1-800-SENSOR-1
TEEJET.COM
TECHNICAL INFORMATION